Table B-4. System-Generated Alert Mask Bit Definitions
Bits
28–31
24–27
20–23
16–19
12–15
8–11
4–7
0–3
where <senMask> has the following bit definitions:
Bit-0: 1 = Send alert for informational events (such as a return to lower severity range or normal).
Bit-1: 1 = Send alert for warning (noncritical) events.
Bit-2: 1 = Send alert for critical events.
Bit-3: Reserved.
where <statMask> has the following bit definitions:
Bit-0: 1 = Send alert when system transitions to a powered-on state.
Bit-1: 1 = Send alert when system transitions to a powered-off state.
Bit-2: 1 = Send alert when watchdog timer detects a system hang.
Bit-3: Reserved.

Alert Filter Properties

The alert filter property group ID is cfgUserAdmin. The object IDs are shown in Table B-5.
Table B-5. Alert Filter Property Group and Object IDs
GroupID
cfgUserAdmin
cfgUserAdmin
cfgUserAdmin
cfgUserAdmin
cfgUserAdmin
cfgRemoteHosts
222
DRAC 4 Property Database Group and Object Definitions
Data
System undefined
System undefined
System undefined
System status alerts
System miscellaneous sensor
System fan sensors
System voltage sensors
System temperature sensors
Object ID
cfgUserAdminPageEmailEnable
cfgUserAdminPageEmailAddress
cfgUserAdminPageEmailCustomMsg
cfgUserAdminAlertFilterRacEventMask
cfgUserAdminAlertFilterSysEventMask
cfgRhostsSmtpServerIpAddr
Type
reserved
reserved
reserved
<statMask>
<senMask>
<senMask>
<senMask>
<senMask>
Object Default Value
FALSE
""
""
0x777777
0x777777
0.0.0.0