Description; Output; Racreset; Synopsis - Dell Remote Access Controller 4 Firmware Version 1.30 User Manual

Remote access controller 4 firmware version 1.30
Table of Contents

Advertisement

Description

The racdump subcommand provides a single command to get dump, status, and general
DRAC 4 board information.
The following commands are executed as a result of the single racdump subcommand:
getsysinfo
coredump
memmap
netstat
getssninfo

Output

The output of the individual commands are displayed.

racreset

NOTE:
To use this command, you must have Configure DRAC 4 permission.
Table A-24 describes the racreset subcommand.
Table A-24. racreset
Subcommand
racreset
NOTICE:
You must wait until the DRAC 4reset is completed before issuing another command. If the
DRAC 4 reset is not completed, you may receive the following error:
Transport: ERROR: (RC=-1)

Synopsis

racadm racreset [hard | soft | graceful] [delay in seconds]
Description
The racreset subcommand issues a reset to the DRAC 4. The user is allowed to select how many
seconds of delay occur before the reset sequence is started. The reset event is written into the
DRAC 4 log.
The default option is soft. If you do not type an option, the racadm CLI waits three seconds and
then runs the soft option with the racreset subcommand.
NOTICE:
You must reboot your system after performing a hard reset of the DRAC 4 as described in
Table A-25.
Definition
Resets the DRAC 4.
racadm <
command name
racadm Subcommand Man Pages
>