3-3. Extension Sensor Cable Specification
Items
Model code
Cable type
Diameter
Operating
temperature range
Insulator
Sheath
Construction
Color of sheath
Advantage
4P-S
Standard cable
-5~+60℃
Irradiated cross
linked formed
polyethylene
Polyvinyl chloride mixture
8-core, 2 pairs without shield + 2 pairs with shield
Gray
Extensible for long
Superior flexibility; ideal for moving place
distances
Specifications
4P-RBT
Semi-heat-resistant
Robotic cable
robotic cable
φ8
-5~+105℃
ETFE plastic (resin)
Heat-resistant
p
olyvinyl chloride
12
4P-URT
4P-HRT
Heat-resistant robotic
0~+150℃
Fluonlex
mixture
Black
Heat treatment and
flexible; ideal for
moving place
cable