Testing Using Keyboard Data (Ats16=8) - 3Com 56K Command Reference Manual

3com officeconnect business modem user guide 56k
Hide thumbs Also See for 56K:
Table of Contents

Advertisement

14-10
C
14: T
HAPTER
ESTING THE
Testing Using
Keyboard Data
(ATS16=8)
C
ONNECTION
1 Send
AT&M0&N3S14.0=0
This command disables error control, fixes the connection rate at 2400
bps, and makes the Business Modem return to command mode when
you type the escape code (
2 Establish a connection with the remote device.
3 If you haven't already done so, arrange with the remote user to
cooperate with the test.
If necessary, set the remote device to acknowledge the remote digital
loopback request. 3Com modems should be set to &T4. (Older 3Com
modems should be set to S16=8.)
4 Send the Business Modem
The Business Modem enters remote digital loopback mode and then goes
back online (O command). It then transmits the test signals, causing the
remote device to enter remote digital loopback mode. The MR status
light flashes during this operation.
5 Type a short message. It will be looped back to your Business Modem by
the remote device and to your screen for verification. (The remote user
will not see your data.)
6 Send the escape code,
If you issue an invalid command, the Business Modem sends an ERROR
message. If you set Register S18, the Business Modem automatically ends
the test when the test timeout is reached. See the example in the
previous section, Stopping a Test for an example of using S18.
If you wish to resume data transmission with the remote device, add the
O command (ATO) after the
this, remember that error control is disabled. Because error control is
negotiated during the connection sequence, its status cannot be changed
until the Business Modem is back on hook and in Command mode.
7 Send
, unless you used a reset command (ATZ or ATZ!
AT&M4
to prepare the Business Modem for testing.
).
+++
.
ATS16=8O
, and then
+++
ATS16=0
string to return online. If you do
ATS16=0
to end the test.
.
)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Officeconnect 56k business