Back Of The Switch; Power Connector; Slot For Redundant Power Supply - HP J4850A Installation And Getting Started Manual

Procurve series 5300xl switches
Hide thumbs Also See for J4850A:
Table of Contents

Advertisement

Back of the Switch

.
Figure 1-8. Example back of 5300xl Series

Power Connector

The Switch 5300xl Series do not have a power switch; they are powered on
when connected to an active AC power source. The switches automatically
adjust to any voltage between 100-127 and 200-240 volts and either 50 or 60
Hz. There are no voltage range settings required.

Slot for Redundant Power Supply

A second, load-sharing redundant power supply (ProCurve Switch gl/xl RPS,
J4839A) can be installed in the back of the Switch 5300xl Series. To provide
true redundancy, this second power supply should be connected to a different
AC power source from the other supply. Then, if one AC power source fails,
the switch will continue to run.
C a u t i o n
The switch redundant power supply is hot swappable, but, as indicated by the
caution statement on the power supply, it must be disconnected from AC
power before being installed or removed.
Because the switch can run on a single supply, removing a redundant supply
will not interrupt switch operation.
AC power connector
pull strap
Introducing the ProCurve Switch 5300xl Series
Back of the Switch
slot for installing optional
redundant power supply
1-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents