Cisco IAD2424-8FXS - IAD 2424 Router System Message Manual page 43

Ethernet access switches
Table of Contents

Advertisement

Chapter 2
Messages and Recovery Procedures
GBIC_SECURITY_CRYPT Messages
This section contains the Cisco GBIC module and SFP module security messages. The switch recognizes
the module as a Cisco module but identifies another problem with it.
The switch supports SFP modules and does not support GBIC modules. Although the error message text
Note
refers to GBIC interfaces and modules, the messages from the switch actually refer to the SFP module
interfaces and modules.
Error Message GBIC_SECURITY_CRYPT-4-ID_MISMATCH: Identification check failed for
GBIC interface [chars].
Error Message GBIC_SECURITY_CRYPT-4-UNRECOGNIZED_VENDOR: GBIC interface [chars]
manufactured by an unrecognized vendor.
Error Message GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC interface [chars] has
bad crc.
OL-9641-01
entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems. For
more information about these online tools and about contacting Cisco, see the
Traceback Reports" section on page
Explanation
This message means that the SFP module was identified as a Cisco SFP module, but the
system was unable to verify its identity. [chars] is the interface in which the module is installed.
Check the list of supported SFP modules for this version of the system
Recommended Action
software. An upgrade might be required for newer modules. Otherwise, verify that the module was
obtained from Cisco or from a supported vendor.
This message means that the SFP module was identified as a Cisco SFP module, but the
Explanation
system was unable to match its manufacturer with one of the known list of Cisco SFP module
vendors. [chars] is the interface in which the module is installed.
Check the list of supported SFP modules for this version of the system
Recommended Action
software. An upgrade might be required for newer modules.
This message means that the SFP module was identified as a Cisco SFP module, but it
Explanation
does not have a valid CRC in the EEPROM data. [chars] is the interface in which the module is
installed.
Check the list of supported SFP modules for this version of the system
Recommended Action
software. An upgrade might be required for newer modules. Even if unrecognized, the module might
operate but with limited functionality.