9-6. Configuration of EtherNet/IP Network

Configure the EtherNet/IP network by the RSLogix5000 software.
RSLogix5000 is a PLC development tool software manufactured by Rockwell Automation, Inc..

9-6-1. Configuration procedure

Set the network configuration by following procedures.
The procedures and settings are different whether EDS file is used or not.
Start setup
EDS file
With EDS file
EDS file
installation
Creation of project
EDS file
With EDS file
Catalog list
(NCW-3DNIP)
I/O Configuration selection
Download project
Finish setup
Without EDS file
-------- Refer to section 9-6-2.
-------- Refer to section 9-6-3.
Create a new project by
Without EDS file
Catalog list
(ETHERNET-MODULE)
I/O Configuration selection
-------- Refer to section 9-6-5.
Download the created project file to PLC.
Install the EDS file to
RSLogix5000 when using the file.
RSLogix5000.
----- Refer to section 9-6-4.
Add
NCW-3DNIP to the project.
For details with using EDS file, refer to section 9-6-4-1.
For details without using EDS file, refer to section 9-6-4-2.