让称重触手可及
Making Weighing More Accessible
⑵ Parameter settings
Rapid parking allocation RDY-CONF-FULL-FUN-STT-FST-L13
Making Weighing More Accessible
Given channel RDY-CONF-FULL-CTL-FR1-NDB
MODBUS address RDY-CONF-FULL-CON-ND1-ADD-2
MODBUS Baud Rate RDY-CONF-FULL-CON-ND1-TBR-9.6
MODBUS format RDY-CONF-FULL-CON-ND1-TF0-8E1
Channel configuration RDY-CONF-FULL-CTL-CHCF-SEP
Command channel 1 RDY-CONF-FULL-CTL-CD1-TER
MODBUS communication fault management RDY-CONF-FULL-FLT-CLL-SLL-NO
⑶ Change the frequency register address of the weighing motor frequency converter on
the speed calibration interface of the weighing scale to 8502
(4) The DI1 pin of the frequency converter is connected to OUT1, the DI3 pin is connected
to the emergency stop button that is normally closed, and the+24V pin is connected to the
emergency stop button and OUT1.
(5) Power on again: After the above parameters are set, the power on parameters will take
effect again.
be careful; Touch screen speed calibration frequency setting value 5 represents 50 Hz
7.4.3 Schneider frequency converter ATV320U07M2C parameter setting
(1) Turn the Dip switch on the communication interface to ON.
(2) Parameter settings
1)、3-03 = 163.84
2)、8-30 = 2
3)、8-32= 2
4)、8-31 = 2
5)、5-11 = 6
6)、1-62 = 0
(3) Change the frequency register address of the weighing motor frequency converter on
the speed calibration interface of the weighing scale to 50009.