General Measure ChexGo CW-60K-V User Manual page 41

Vertical checkweigher (mcgs+c01 version)
Table of Contents

Advertisement

Overweight or
underweight alarm and
stop
The main page
displays the
information of
overshoot and
undershoot
The main page will
display only the weight
test result
Auxiliary display of
real-time weight
Units
Minimum indexing
Check scale for
stability range
Judge the range of
stability;
Zero tracking range
Clear range
Automatic zeroing at
startup
product or the object to be weighed exceeds the set upper
limit, it will alarm and stop
Display on the main page that the result of this test product is
out of tolerance or under tolerance and the device will stop.If
you need to use this function, you need to move forward the
discharge photoelectric position, please contact our technical
department for details
On the main page, it shows that the result of this test is out of
tolerance, under tolerance, or qualified
Only the product weight test result of this test is displayed on
the main page
Display the detected real-time product weight on the main
page
g/kg/t Optional
0.001. 0.002. 0.005. 0.010. 0.020. 0.050 Optional
When calibrating the scale, the weight variation range is
judged to be stable within this setting value
During the stabilization time, the range of weight variation is
judged to be stable within this setting value
Weight value within this range, automatically clear zero
The range at which the scale table is zeroed out during
weighing
Perform zero clearing once the scale platform is started
-35-
让称重触手可及
Making Weighing More Accessible
Making Weighing More Accessible

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ChexGo CW-60K-V and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Chexgo cw-60k

Table of Contents