2) P9=rated current of the motor, please refer to the motor nameplate for details.
3)、P80 =0.75
Making Weighing More Accessible
4)、P96 =1
Press run to start until P96 becomes 3.
(3) Parameter settings (please set them in order and cannot adjust the order)
1)、P17 = 2
2)、P117 = 2
3)、P118= 96
4)、P119= 0
5)、P121=9999
6)、P122=9999
7)、P179=24
8)、P338=1
9)、P339=2
10)、P340=1
11)、P342=1
12)、P549=1
13) P79=2 (must be the last setting)
(4) Change the frequency register address of the weighing motor frequency converter on
the speed calibration interface of the weighing scale to 14.
(5) Power on again: After the above parameter settings are completed, the power on
parameters will take effect again.
The above methods were not successful. Please download the corresponding model
frequency converter manual from the Mitsubishi official website or call our technical
department.

7.4.2 Schneider frequency converter ATV320U07M2C parameter setting

(1) Restore factory settings for parameters first (CONF-FCS-FCS, - FRY-ALL (confirm)
Exit to FRY-GFS (set to YES and hold for two seconds)