Stage Box Data Conversion
To open the Stage Box Data Conversion dialog box, click the [Stage Box Data Conversion] button in the System Setup
dialog box.
Use this dialog box to convert HA settings and input patch settings accordingly if, for example, you want to use (on an
M7CL-48ES system) data stored by a system that features SB168-ES units connected to M7CL-48 slots.
Analog devices
Internal HA
M7CL-48
M7CL using External HA via Slot ➞
A
M7CL-48ES
Converts the patch settings as follows:
INPUT 1-16
INPUT 17-32
INPUT 33-48
ST IN 1L-4R
SLOT1 IN 1-16
SLOT2 IN 1-16
SLOT3 IN 1-16
TALKBACK
OMNI OUT 1-16
SLOT1 OUT 1-16
1
2
3
4
5
3
2
(With MY16-ES64 and
MY16-EX installed)
(
)
→
SLOT1 IN 1-16
*
(
)
→
SLOT2 IN 1-16
*
(
)
→
SLOT3 IN 1-16
*
(
)
→
OMNI IN 1-8
*
(
)
→
ES IN 1-16
*
(
)
→
ES IN 17-32
*
(
)
→
ES IN 33-48
*
→
TALKBACK
→
SLOT1 OUT 1-16
→
ES OUT 1-16
1
3 x SB168-ES
4
M7CL-48
SLOT2 OUT
No assignment
SLOT3 OUT 1-16
2TR DIGITAL OUT
(*) The same HA settings will be used.
8
3 x SB168-ES
EXT-ES HA
M7CL-48ES
→
1-8
ES OUT 17-24
→
9-16
OMNI OUT 1-8
→
SLOT2 OUT 1-16
→
SLOT3 OUT 1-16
→
2TR DIGITAL OUT
M7CL V3 Editor Owner's Manual