22
152.
Description
Parameter size 1B
Default value 0 (cancel mode)
Available
153.
Description
Parameter size 1B
Default value 0 (cancel mode)
Available
154.
Description
Parameter size 2B
Default value 5 (0.5s)
Available
confIguratIon
First channel – reaction to input change in delayed/auto OFF
This parameter determines how the device reacts when
changing state of S1 input in timed modes for the 1
channel.
0 – cancel mode and set default state
1 – no reaction, mode runs until it ends
values
2 – reset timer, start counting time from the beginning
Second channel – reaction to input change in delayed/auto
Only in Double Smart Module
This parameter determines how the device reacts when
changing state of S2 input in timed modes for the 2
channel.
0 – cancel mode and set default state
1 – no reaction, mode runs until it ends
values
2 – reset timer, start counting time from the beginning
First channel – time parameter for delayed/auto OFF and
This parameter enables setting time parameter used in
timed modes (delayed/auto OFF and flashing) for fthe 1
channel.
0 – 0.1 seconds
values
1-32000 – 0.1-3200 seconds, 0.1s step
modes
OFF modes
flashing modes
st
nd
st
Need help?
Do you have a question about the SMART MODULE and is the answer not in the manual?
Questions and answers