ENG
Technical Information
• Controlled by FIBARO system devices or any Z-Wave controller.
Electronic switch is a remote control unit.
• Microprocessor control.
• Active element: electromagnetic, micro-gap relay switch.
• The device may be operated by momentary and toggle
push-buttons.
To be installed in wall switch boxes of dimensions allowing for
installation, conforming to provisions of applicable regulations.
I General information about Fibaro system
FIBARO is a wireless system, based on Z-Wave technology.
FIBARO provides many advantages when compared to similar
systems. In general, radio systems create a direct connection
between the receiver and transmitter. But the radio signal is
weakened by various obstacles located on its path (apartment
OPERATING MANUAL
walls, furniture, etc.) and in extreme cases it fails to transfer
required data. The advantage of FIBARO system is that its devices
RELAY SWITCH
apart from being transmitters and receivers of signals, they are also
a signal "duplicators". When a direct connection path between the
FGS-212-EN-A-v1.01
transmitter and the receiver can not be established, the connection
may be achieved through other intermediate devices.
FIBARO is a bi-directional wireless system. It means that the signal
is not only sent to the receivers but also the receivers send the
confirmation of its reception. This operation confirms their status so
to check whether they are active. Safety of the FIBARO system
Remotely Controlled Relay Switch of Fibaro System is designed to
transmission is comparable to the safety of transmission in data bus
operate in a wall switch box or in locations where the control of an
wired systems.
electric device (up to 2.5kW) is needed.
FIBARO operates in the free band for data transmission. The
It is also possible to send a signal to any system that is to be
frequency depends on radio regulations in individual country . Each
integrated with Fibaro system.
FIBARO network has its own unique network identification number
(home ID), which is why it is possible to co-operate two or more
Specifications
independent systems in a single building without any interference.
Although Z-Wave is quite new technology, it has already become
Power supply:
110 - 240V ~
recognizable and officially binding standard, similarly to Wi-Fi.
50 - 60Hz
Many manufacturers in various industries offer solutions based on
Z-Wave technology, guaranteeing their compatibility. This means
Power consumption:
to 0,8W
that the system is open and it may be extended in the future. Find
more information at www.fibaro.com.
Operational temperature:
0 - 35°C
FIBARO generates a dynamic network structure. After FIBARO
Dimensions (L x W x H):
42,50 x 38,25 x 20,30 mm
system is switched on, the location of its individual components is
automatically updated in real-time through status confirmation
For installation in boxes:
Ø ≥ 50mm
signals received from devices operating in a "mesh" network.
Rated load current:
10A for resistive load*
The In-Wall Relay Switch is hereinafter referred to as Fibaro
Switch. It is designed to switch on/off devices connected to its
Overcurrent protection:
required external 10A circuit
terminals using radio waves, controllers and a push button directly
breaker
connected to Fibaro Switch.
Active element:
micro-gap relay switch μ
II Assembling Fibaro Switch
Device control:
remotely - radio waves
directly - push buttons
Radio protocol:
Z-Wave
Radio signal power:
1mW
Radio Frequency:
868,4 MHz EU;
908,4 MHz US;
921,4 MHz ANZ;
869,0 MHz RU;
865,2 MHz IN;
Range:
up to 50 m outdoors
up to 30 m indoors
(depending on building materials)
Comply with EU directives:
RoHS 2011/65/EU
LVD 2006/95/EC
EMC 2004/108/EC
R&TTE 1999/5/EC
1. Before installation ensure that the voltage supply is
disconnected.
2. Connect Fibaro switch as shown on the diagram.
3. Place the switch in the switch box.
4. Arrange the antenna (tips are presented further).
Single switch - mains electricity power connection
L
N
Double switch - mains electricity power connection
L
N
Fig.1 Wiring diagrams for Fibaro Switch.
NOTES FOR THE DIAGRAM:
N - terminal for neutral lead
L - terminal for live lead
IN - input terminal for load power supply
Q - output terminal of the load
CAUTION
S2 - terminal for key no. 2
Read this manual before attempting to install
S1 – terminal for key no. 1 (has the option of entering the device in
the device! Failure to observe recommendations
learning mode)
!
included in this manual may be dangerous or cause
B- service button (used to add or remove a device from the system)
a violation of the law. The manufacturer, Fibar
Group S.A. will not be held responsible for any loss
or damage resulting from not following the
instructions of operating manual.
!
CAUTION
Product must be installed on a 10A line.
DANGER
Danger of electrocution! Electronic switch is
designed to operate in electrical home installation.
Faulty connection or use may result in fire or electric
shock.
DANGER
Danger of electrocution! All works on the device
Fig.2 Installation of Fibaro Relay Switch in wall switch box.
may be performed only by a qualified and licensed
electrician. Observe national regulations.
CAUTION
!
The switch box must be compliant with the relevant
DANGER
national safety standards and it's depth should not
be less than 60mm.
Danger of electrocution! Even when the device is
turned off, voltage may be present at its terminals.
Any
works
introducing
changes
into
the
CAUTION
configuration of connections or the load must be
The device is designed for installation in wall
always performed with disconnected voltage
!
(disable the fuse).
switch boxes and can work only with the electrical
connectors compliant with the relevant safety
standards.
CAUTION
Do not connect the device to loads exceeding
NOTE
!
i
recommended
values.
Connect
only
in
Durability of the device depends on applied load.
For resistive load (light bulbs, etc.) and 6,5A current
accordance with the diagram presented in the
per channel, the durability exceeds 200 000
manual. Improper connections may be dangerous.
switches.
TIPS FOR ARRANGING THE ANTENNA:
i
Locate the antenna as far from metal elements as
possible (connecting wires, bracket rings, etc.) in
order to prevent interferences.
i
Metal surfaces in the direct vicinity of the antenna
(e.g. flush mounted metal boxes, metal door
frames) may impair signal reception!
i
Do not cut or shorten the antenna - its length is
perfectly matched to the band in which the system
operates.
NOTE
i
It should be noted that only the push-button
connected to S1 terminal and service push-button
S1 S2
IN
L
N
B enables "learning" mode (Include/ Exclude).
Q
B
SWITCH
DICTIONARY:
• Adding (Inclusion) - Z-Wave device learning mode, allowing to
add the device to existing Z-Wave network.
• Removing (Exclusion) - Z-Wave device learning mode, allowing
to remove the device from existing Z-Wave network.
• Association (linking devices) - direct control of other devices
within the Z-Wave system network.
• Multi-channel association - controlling other multi-channel
devices within the Z-Wave network.
III Activating Fibaro Switch
1. Installing the Fibaro Switch
S1 S2
IN
L
N
Q
STEP 1
B
Connect the device in accordance with the wiring diagram
SWITCH
presented in Figure 1. Switch on the mains voltage.
[Adding/Removing] Fibaro Switch [to/from] Z-wave network
STEP 2
Fibaro Switch must be placed within the range of Home Center
controller, as adding mode requires direct communication with the
controller.
STEP 3
Find key no. 1 which allows to switch circuit 1 on, in accordance
with the diagram
STEP 4
Set the Home Center controller in add/remove mode (see the
controller's manual)
STEP 5
Add Fibaro Switch to the network by pushing three times key no. 1
or push-button B located inside the housing of the device. For
toggle switch perform 3 position changes.
During the installation it is recommended to use a
momentary key connected to S1.
STEP 6
The controller indicates when the device is correctly added to the
network, (see the manual of Home Center controller).
CAUTION
Fibaro Switch cancels the "learning" mode after
!
key no. 1 is pressed once. Therefore, pressing key
no. 1 four times will not add the devices to the
network. The same applies to push-button B.
CAUTION
Fibaro Switch is set by default to operate with
momentary switches (i.e. single-pole switch or bell
!
switch). While adding Fibaro Switch to the network
with toggle switches, ensure that all switch contacts
are open (off), because closing them results in
activating the push-button and this will prevent
adding the device to the network.
2. Resetting Fibaro Switch
Fibaro Switch provides two methods for resetting.
Method I : Reset by removing Fibaro Switch from the existing
Z-Wave network. The device may be removed using the controller
that has the ability to include/exclude devices from/to Z-Wave
network (see the manual of controller).
Method II : Reset by holding B button for 3 sec. after connecting
mains voltage to the Switch
3. Controlling Fibaro Switch by momentary or toggle
V Configuration
switches.
The following settings are available in the Fibaro interface as
Momentary switch (after releasing the push-button a spring
simple options that may be chosen by selecting the appropria-
automatically pushes back and disconnects the button)
te
box.
- Turning on/off circuit 1 or 2 - briefly press the push-button
In order to configure Fibaro Switch (using the Home Center
corresponding to a chosen circuit (see diagram).
controller), go to device options by clicking the following icon:
Toggle switch (operates as a two-position switch, it has no
Select „Advanced" tab.
spring that would push back the device after releasing manual
pressure)
Parameter No. 1 - Activate / deactivate functions ALL ON / ALL
- Turning on/off the circuit - change the position of selected
OFF.
push-button from the current position.
Default value: 255
Options for changing parameter 255, 0, 1, 2
4. Controlling Fibaro Switch using a command: ALL
Available configuration parameters:
ON / ALL OFF
255 - ALL ON active, ALL OFF active.
0 - ALL ON is not active ALL OFF is not active
Fibaro Switch responds to commands ALL ON / ALL OFF that may
1 - ALL ON is not active ALL OFF active
be sent by the controller. ALL ON / ALL OFF commands are usually
2 - ALL ON active ALL OFF is not active
implemented in Z-Wave remote control.
Parameter No. 3 - Auto off relay after specified time, with the
By default, Fibaro Switch accepts both active commands ALL ON
possibility of manual override - immediate Off after button
and ALL OFF. Settings may be changed by entering an appropriate
push.
value into configuration register no. 1 (see configuration)
Default value: 0
Available settings:
0 - manual override disabled. After single button push the relay
turns on and automatically turns off after specified time.
5. Controlling Fibaro Switch using Home Center
1 - manual override enabled. After single button push the relay
controller
turns on and automatically turns off after specified time. Another
button push turns the relay off immediately.
After adding Fibaro Switch to the network, it will be represented in
Home Center by the following icon:
Parameter No. 4 - Auto off.
Default value: 0
Available settings:
[1- 65535] (0,1 s – 6553,5 s) Time period for auto off, in miliseconds
0 - Auto off disabled
Parameter No. 6 - Sending commands to control
assigned to 1-st association group (key no. 1).
Default value: 0
Available configuration parameters:
0 - commands are sent when device is turned on and off
Fig.3 Icon of Fibaro Switch shown by Home Center controller
1 - commands are sent when device is turned off. Enabling device
does not send control commands. Double-clicking key sends 'turn
on' command, dimmers memorize the last saved state (e.g. 50%
By default, FGS-212 device has a second hidden icon.
brightness).
It represents the second, virtual channel of the device triggered by
the second key. The user may add the association to this channel
2 - commands are sent when device is turned off. Enabling device
or trigger a scene.
does not send control commands. Double-clicking key sends 'turn
on' command and dimmers are set to 100% brightness.
Turning on/off the device connected to Fibaro Switch is performed
NOTE: Parameter 15 value must be set to 1 to work properly.
by pressing ON/OFF icon.
This activates the double-click functionality - dimmer/roller
shutter control.
IV Association
Parameter No. 13 - Assigns bistable key status to the device
status.
Association enables Fibaro Switch to directly control a device
Default value: 0
included in Z-Wave network e.g. Dimmer, Switch (ON-OFF), Roller
Shutter or scene (scene may be controlled only through the Home
Available configuration parameters:
Center controller).
0 - [On / Off] device changes status on key status change.
1 - Device status depends on key status: ON when the key is ON,
i
OFF when the key is OFF.
Association ensures direct transfer of control
commands between devices, and is performed
without participation of the main controller.
i
Fibaro Switch provides association of three groups.
1st group is assigned to key no. 1
Parameter No. 14 - Switch type connector, you may choose
between momentary and toggle switches.
2nd group is assigned to key no. 2
Default value: 1
3rd group reports state of devices. Only one device can be
Options for changing the parameter:
associated to this group.
0 - momentary switch
1 - toggle switch
Fibaro Switch enables user to control up to 5 normal devices, and
5 MultiChannel devices in group no. 1 and no. 2, group no. 3 has
only one field. One field is reserved for the network controller.
Parameter No. 15 - Operation of the Dimmer and Roller Shutter
Controller - enabling this option allows the user to dim
lighting/shut roller by associating Dimmer/Roller Shutter
To add an association (using the Home Center controller), go to
Controller and holding or double press of double switch (only
device options by clicking the following icon:
mono-stable switch).
Default value: 0
Select the "device options" tab. Then specify to which group and
what devices are to be associated. Sending relevant information to
Available configuration parameters:
0 - Dimmer/Roller Shutter Controller control is not active
devices added to associated groups may take even a few minutes.
1 - Dimmer/Roller Shutter Controller control is active
WARNING
!
When Fibaro Switch sends control commands and
Parameter No. 16 - Saving the state of the device after a power
a new command is issued, then the current one
failure. Fibaro Switch returns to the last position saved before
command transmission is interrupted to send new
a power failure.
commands.
Default value: 1
Options for changing the parameter 0-1
FGS-212 Fibaro Switch supports the operation of multi-channel
devices. Multichannel devices are devices that include two or more
0 - Fibaro Switch does not save the state after a power failure, it
circuits inside one physical unit.
returns to "off" position
1 - Fibaro Switch saves its state before power failure
devices
Remote control from Fibaro System is still
possible. This function is useful when you want
display status of external devices, e.g. Motion
Sensor, in Fibaro System.