FIBARO SMART MODULE Operating Manual page 19

Hide thumbs Also See for SMART MODULE:
Table of Contents

Advertisement

31.
This parameter determines to which alarm frames and
how the device should react. The parameters consist of 4
Description
bytes, three most significant bytes are set according to the
official Z-Wave protocol specification.
Parameter size 4B
[0x05, 0xFF, 0x00, 0x00]
Default value
(Water Alarm, any notification, no action)
1B [MSB] – Notification Type
2B – Notification Status
Available
3B – Event/State Parameters
values
4B [LSB] – action:
0x00 – no action, 0x01 – turn ON, 0x02 – turn OFF, 0x03
– turn ON/OFF continuously
32.
This parameter determines to which alarm frames and
how the device should react. The parameters consist of 4
Description
bytes, three most significant bytes are set according to the
official Z-Wave protocol specification.
Parameter size 4B
[0x01, 0xFF, 0x00, 0x00]
Default value
(Smoke Alarm, any notification, no action)
1B [MSB] – Notification Type
2B – Notification Status
Available
3B – Event/State Parameters
values
4B [LSB] – action:
0x00 – no action, 0x01 – turn ON, 0x02 – turn OFF, 0x03
– turn ON/OFF continuously
33.
This parameter determines to which alarm frames and
how the device should react. The parameters consist of 4
Description
bytes, three most significant bytes are set according to the
official Z-Wave protocol specification.
Parameter size 4B
[0x02, 0xFF, 0x00, 0x00]
Default value
(CO Alarm, any notification, no action)
Alarm configuration - 2
Alarm configuration - 3
Alarm configuration - 4
slot
nd
slot
rd
slot
th
19
confIguratIon

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMART MODULE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Double smart moduleFgs-214Fgs-224

Table of Contents