RAC and VRF J-II/V-II/VR-II Series Error Codes
30
1E
31
1F
32
20
33
21
34
22
36
24
37
25
38
26
39
27
40
28
41
29
42
2A
43
2b
44
2C
45
2d
46
2E
47
2F
48
30
49
31
50
32
51
33
52
34
53
35
54
36
55
37
56
38
117
11
118
12
119
13
120
14
121
15
122
16
123
17
133
21
134
22
RAC
135
23
Inverter
Models G
136
24
series
137
25
VRF
138
26
J-II/V-II/VR-II
139
27
Series
140
28
141
29
149
31
150
32
151
33
152
34
153
35
154
36
USER MANUAL Version 1.0.9
3-way valve temperature sensor error
Connected indoor unit error
Indoor MANUAL AUTO switch error
reverse VDD permanent stop protection
VDD permanent stop protection
Excessive high pressure protection on cooling
P.F.C. circuit error
Indoor signal error
Indoor signal error
Indoor heat exchanger temperature sensor (inlet) error
Outdoor heat exchanger temperature sensor (middle)
error
Power supply frequency detection error
Compressor temperature error
4-way valve error
Heat sink thermistor P.F.C. error
Indoor unit damper error
Inverter error
Low pressure error
Refrigerant circuit address set-up error
Master unit, Slave unit set-up error
Connected the indoor number set-up error
P.F.C. printed circuit board error
Indoor fan 2 error
Control box thermistor error
Indoor unit CT error
Indoor fan motor 1 driving circuit error
Indoor fan motor 2 driving circuit error
Serial communication error between indoor/outdoor units
Remote controller communication error
Communication error between outdoor units
Network communication error
Scan error
Peripheral unit communication error
Electricity charge apportionment error
Indoor unit initial setting error
Indoor unit capacity abnormal
Incompatible series connection error
Connection unit number error
Connection pipe length error
Indoor unit address setting error
Master/slave unit setting error
Other setting error
Connection unit number error in wired remote controller
system
Indoor unit power supply abnormal
Indoor unit main PCB error
Indoor unit display PCB error
Power relay error
Indoor unit manual auto switch error
Heater relay error