Function Blocks/ITEMs Incompatible with Earlier Versions

1-5-6 Incompatibility with Versions Earlier than Version 4.0

Function Blocks
Incompatible with Earlier
Versions
1-5-7 Incompatibility with Versions Earlier than Version 5.0
Function Blocks
Incompatible with Earlier
Versions
1-5-8 Incompatibility with Versions Earlier than Version 5.2
Function Blocks
Incompatible with Earlier
Versions
30
• If an earlier version of the Loop Control Board is used with CX-Process Tool
version 3.20 or higher, these function blocks can be registered but the data for
the function blocks won't be downloaded to the Loop Control Unit when LCU
element data is downloaded. (The supported function blocks will be down-
loaded normally.)
• If Loop Control Board version 1.20 or later is used with a lower version of the
CX-Process Tool, these function blocks cannot be registered in the CX-Pro-
cess Tool, so they cannot be downloaded to the Loop Control Unit.
If these function blocks have been downloaded to the Loop Control Unit al-
ready, the data for these function blocks won't be uploaded from the Loop Con-
trol Unit. The supported function blocks will be uploaded normally. (If Upload
New is selected, the unsupported function blocks will be empty.)
The following function blocks can be used only with LCB01/LCB05 version 2.0 or
later, or LCB03, together with the CX-Process Tool version 4.0 or higher.
Ai4 Terminal (PTS51/52) (Block Model 590), Ao2 Terminal (DA021)
(Block Model 591), Ai4/Ao2 Terminal (MAD42) (Block Model 592)
• If an earlier version of LCBjj is used with a lower version of the CX-Process
Tool, these function blocks cannot be registered in the CX-Process Tool, so
they cannot be downloaded to the LCBjj.
The following function blocks can be used only with LCB03 and only if LCB03 is
used together with CX-Process Tool version 5.1 or higher. If used with a lower
version of the CX-Process Tool, the following function blocks cannot be regis-
tered and, therefore, cannot be downloaded to the Loop Control Board.
Gradient PV Mode Converter (Block Model 021), Gradient SP Mode
Converter (Block Model 022), Gradient PID (Block Model 024), Gradient
Precompensator (Block Model 023)
The following function blocks can be used only with LCB01/LCB05 version 3.0 or
later, or LCB03 version 3.0 or later, together with the CX-Process Tool version
5.0 or higher.
• The following function blocks cannot be registered if LCB01/LCB05 version
3.0 or later, or LCB03 version 3.0 or later, is used together with a version of
CX-Process Tool lower than version 5.0. For this reason, these function blocks
cannot be downloaded to the Loop Controller
AI16 Terminal (AD161), AI2 Terminal (PTS15/16, PDC15), Switch Instru-
ment (Block Model 225)
• The following settings cannot be used if LCB01/LCB05 version 3.0 or later, or
LCB03 version 3.0 or later, is used together with a version of CX-Process Tool
lower than version 5.0.
Switch action direction command (ITEM 053), RUN/STOP switch (ITEM
093), and MV at stop (ITEM 094) in Basic PID (Block Model 011) or
Advanced PID (Block Model 012)
Note For details on which actual ITEM this restriction applies to, refer to the ITEM list
for the relevant function block in the Function Block Reference Manual.
The following function blocks cannot be registered on the CX-Process Tool
when LCB01/05 version 3.5 or later or LCB03 version 3.5 or later is used with
Section
1-5