Omron WS02-LCTC1-EV5 - V5.2 REV 12-2008 Manual page 104

Table of Contents

Advertisement

Overview of User Interface
Menu
Submenu/
Command
Execution,
Transfer
continued
to LC
Transfer
from LC
Operation
Compare with LC
Monitor
Backup
Data
a a
Operation
O
Check Version
Delete Registered
Function Block
78
Selected
Transfers the data in the specified Loop Controller or
function block in the current function block file to the
specified Loop Controller connected online.
FBD In-
Downloads layout information for a function block
formation
connection diagram to an LCBjj.
Memory
Transfers function block connection diagrams, tags,
Card
comments, and annotations to a Memory Card.
Tag Data
Transfers block diagram data, tags, comments, and
annotation data to a Memory Card.
(LCB01/LCB05/LCB05-GTC version 3.0 or higher)
Previous
Uploads function block data from the specified Loop
Controller connected online to replace the data in the Loop
Controller in the current function block file or the current
function block.
New
Newly uploads function block data from the specified Loop
Controller connected online to be read to the Loop
Controller in the current function block file or the current
function block.
Run/Stop
Starts or stops the Loop Controller, including hot or cold
Com-
starts.
mand
Monitor
Executes monitor control of the System Common block.
Run
Status
Clear All
Clears function block data from the Loop Controller.
Compares the data in the current function block file and
the data in the Loop Controller connected online or data in
a file. Also compares the data in the current function block
file and the data in another file.
ITEM List
Monitors (lists) all of the selected function block's ITEM
data. It is also possible to download the data of individual
ITEMs.
Tuning
Makes online changes to settings such as the function
Screen
block's PID constants and SPs.
All Stop
Stops all windows in which diagrams are being validated,
ITEM lists are being monitored, and tuning screens are
being displayed.
Backup
Copies the function block data in the RAM in the Loop
Controller to the flash memory in the Loop Controller.
Recovery
Restores the function block data in the flash memory in
the Loop Controller to the RAM in the Loop Controller.
Checks whether the version of the Loop Controller
connected on line agrees with the version of the
CX-Process Tool, and displays the result.
Execution
Deletes the registered function block (in the
Loop Controller) while online.
Description
Section
2-2
Conditions for
selection
When a Loop
Controller is
selected or function
block is selected
When an LCB
element, function
block, or function
block diagram is
selected
When a Loop
Controller is
selected
When a Loop
Controller is
selected
When a Loop
Controller, function
block, or function
block diagram is
selected
When a Loop
Controller is
selected
When the selected
item is not the
Project Workspace
j
p
or the function block
th f
ti
bl
k
file
When the selected
item is not the
Project Workspace
When the cursor is
positioned on a
function block that
has been pasted
h
b
t d
When the selected
item is not the
Project Workspace
When a Loop
Controller is
Co
o e s
selected
When a Loop
Controller is
selected
When a function
block is selected

Advertisement

Table of Contents
loading

Table of Contents