Editing Sequence Settings; Sequence Editing Screen - Omron WS02-NCTC1-E - 07-2001 Operation Manual

Hide thumbs Also See for WS02-NCTC1-E - 07-2001:
Table of Contents

Advertisement

Editing Sequence Settings

Clearing to Default
Settings
1,2,3...
To Copy Axes
1,2,3...
4-4

Editing Sequence Settings

4-4-1

Sequence Editing Screen

4-4-2
Editing Sequence Settings
56
Use the following procedure to clear the axis settings to their default values.
(Refer to 4-2-4 Clearing Settings for details.)
1. On the Parameter Setting Editing Screen, either select Edit/Defaults Set-
ting, or right-click and select Defaults Setting from the pop-up menu.
2. Select the axis whose settings are to be cleared to the default values.
3. Click the OK Button.
4. A dialog box will be displayed asking if the settings should be returned to
their default values. Click the OK Button.
For 2-axis and 4-axis NC Units, data can be copied from one axis to another
axis by selecting the source and destination axes. (Refer to 4-2-5 Copying
Axis Settings for details.)
1. Select Edit/Copy Axis.
2. Under From and To, select the axes to be copied from and to respectively.
3. Click the OK Button.
On the project tree, either double-click Edit Sequence, or select it and press
the Enter Key.
For single axis NC Units, only the Table 1 Tab will be displayed; for 2-axis NC
Units, only the Table 1 and Table 2 Tabs will be displayed.
Example: The following will be displayed as the 4-axis NC Unit sequence Set-
ting Editing Screen.
Table Tabs
Enter each sequence setting in order. Refer to 4-2-2 Editing Settings for edit-
ing methods
The following items and setting ranges will be displayed.
Item
Position data
Pulses: C0000001 to 3FFFFFFF Hex (±1,073,741,823)
mm or inches: pulse set value × pulse rate
Axis set
X/Y/Z/U
Output code
00 to 0F Hex (0 to 15)
Section 4-4
Setting range

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ws02-nctc1-e cx-position

Table of Contents