NC Unit Error Logs
Item
Name
Positioning
Sequence data error 3000
sequences
Dwell times
Dwell time error
98
Code
One of the following errors occurred in
to
the positioning sequence:
3099
The completion code is not in the range
0 to 6.
The initial speed number is not in the
range 00 to 99.
The acceleration time number is not in
the range 0 to 9.
The deceleration time number is not in
the range 0 to 9.
The target speed number is not in the
range 00 to 99.
The dwell time number is not in the
range 00 to 19.
One of the following errors occurred in
the axis designation:
The Y, Z, or U axis was specified for a 1-
axis NC Unit.
The Z or U axis was specified for a 2-
axis NC Unit.
More than one axis is specified for inter-
rupt feeding or speed control, or all axis
designation settings are set to 0.
(The last two digits of the code indicate
the position data number (00 to 99)
where the error occurred.)
4001
These codes indicate that a dwell time
to
is outside the settable range (0 to 9.99
4019
s).
(The last two digits of the code indicate
the dwell time number (00 to 19) where
the error occurred.)
Cause
Section 10-1
Clearing
Operation
method
after error
Transfer the data
When this
again after
error occurs
checking and
during data
correcting it.
transfer, all
data (includ-
ing the data
with the error)
specified for
transfer will
be lost.
All operating
axes will be
decelerated
to a stop.