Omron WS02-NCTC1-E - 07-2001 Operation Manual page 57

Hide thumbs Also See for WS02-NCTC1-E - 07-2001:
Table of Contents

Advertisement

Overview
Acceleration/Deceleration
(X/Y/Z/U Axes: #1 to #9)
Dwell Time (X/Y/Z/U Axes:
#1 to #19)
Zone (X/Y/Z/U Axes: Zone
0 to Zone 2)
46
either hexadecimal or decimal format depending on the setting of the display
format.
Item
Speed (See notes 1
and 2.)
Notes
1. Settings can be entered and displayed in either hexadecimal or decimal
format depending on the setting of the display format.
2. When the displayed value's set unit is Pulse. When the set unit is mm or
inches and the pulse rate is set to other than 1, the value displayed will
change.
3. The speeds set above can be set as interpolation speeds. However, make
sure that the maximum speed of individual axes does not exceed
500,000 (pps) or the maximum speed set in the parameter settings.
Only the X-axis settings are used for the CS1W-NC113/133 and CJ1W-
NC113/133, and only the X- and Y-axis settings are used for the CS1W-
NC213/233 and CJ1W-NC213/233. Settings can be entered and displayed in
either hexadecimal or decimal format depending on the setting of the display
format.
Item
Acceleration
(See note.)
Deceleration
(See note.)
Note Settings can be entered and displayed in either hexadecimal or decimal for-
mat depending on the setting of the display format.
Only the X-axis settings are used for the CS1W-NC113/133 and CJ1W-
NC113/133, and only the X- and Y-axis settings are used for the CS1W-
NC213/233 and CJ1W-NC213/233. Settings can be entered and displayed in
either hexadecimal or decimal format depending on the setting of the display
format.
Item
Dwell time (See
note.)
Note Settings can be entered and displayed in either hexadecimal or decimal for-
mat depending on the setting of the display format.
Only the X-axis settings are used for the CS1W-NC113/133 and CJ1W-
NC113/133, and only the X- and Y-axis settings are used for the CS1W-
NC213/233 and CJ1W-NC213/233. Settings can be entered and displayed in
either hexadecimal or decimal format depending on the setting of the display
format.
Item
Zone (See notes 1
and 2.)
Note
1. Settings can be entered and displayed in either hexadecimal or decimal
format depending on the setting of the display format.
2. When the displayed value's set unit is Pulse. When the set unit is mm or
inches and the pulse rate is set to other than 1, the value displayed will
change to specified set value × Pulse Rate.
Setting range
00000000 to 000F4240 Hex (0 to 1,000,000) (pps)
Setting range
00000000 to 0003D090 Hex (0 to 250,000) (ms)
00000000 to 0003D090 Hex (0 to 250,000) (ms)
Setting range
0000 to 03E7 Hex (0.00 to 9.99) (s)
Setting range
C0000001 to 3FFFFFFF Hex (±1,073,741,823) (pulses)