Omron WS02-NCTC1-E - 07-2001 Operation Manual page 68

Hide thumbs Also See for WS02-NCTC1-E - 07-2001:
Table of Contents

Advertisement

Editing Sequence Settings
To Clear to Default
Settings
To Copy Axes
Item
Position designa-
tion
End code
Dwell #
Accel. #
Decel. #
Start speed
Target speed
No particular axis is allocated to Tables 1 to 4, but between tables the same
axis cannot be specified in the same sequence.
Example: The following screen will be displayed after setting sequence Num-
bers 0 to 3 in Table 1 for a 4-axis NC Unit.
Use the following procedure to clear specific settings to their default values.
(Refer to 4-2-4 Clearing Settings for details.)
1,2,3...
1. On the Sequence Setting Editing Screen, select the settings to be cleared
to the default values, or designate the range by clicking and dragging.
2. Select Edit/Clear
For 2-axis and 4-axis NC Units, data can be copied from one axis to another
axis by selecting the source and destination axes. (Refer to 4-2-5 Copying
Axis Settings for details.)
1,2,3...
1. Select Edit/Copy Axis.
2. Under From and To, select the axes to be copied from and to respectively.
3. Click the OK Button.
0 (absolute position) or 1 (relative position)
00 to 06 Hex (0 to 6)
0 = terminating; 1 = automatic; 2 = continuous; 3 = bank end; 4
= speed control; 5 = interrupt feeding (forward direction); 6 =
interrupt feeding (reverse direction)
00 to 13 Hex (0 to 19) (no dwell time for 0)
0 to 9 Hex (0 to 9) (0 = Acceleration time in parameter settings)
0 to 9 Hex (0 to 9) (0 = Deceleration time in parameter settings)
00 to 63 Hex (0 to 99)
00 to 63 Hex (0 to 99)
Section 4-4
Setting range
57

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ws02-nctc1-e cx-position

Table of Contents