Multiple Unit Monitoring - Omron WS02-NCTC1-E - 07-2001 Operation Manual

Hide thumbs Also See for WS02-NCTC1-E - 07-2001:
Table of Contents

Advertisement

Monitoring NCs
8-1
Monitoring NCs
1,2,3...
8-2

Multiple Unit Monitoring

1,2,3...
82
Use the following procedure to display NC Unit present positions, error codes,
sequence numbers, and I/O status on the NC Monitor.
1. On the project tree, select the NC Unit to be monitored and select Online
(L)/Monitor (M). If another NC Unit is to be monitored after NC monitoring
has been started, select the new NC Unit from the Unit No. field.
Example: The following will be displayed as the 4-axis NC Unit Monitoring
Screen.
The present position of each axis is shown under Present Position; the er-
ror code number and description are shown under Error Code; and the se-
quence number and I/O status of each axis are shown under Status. A red
light indicates that an I/O signal is ON.
For error details, refer to the relevant NC Unit Operation Manual, or click
the Help Button.
Use the following procedure to monitor the status of up to four NC Units simul-
taneously.
1. On the project tree, select an PC or NC, and then select Online (L)/Mon-
itor Units (F). After starting Unit monitoring, the Units selected for moni-
toring can be changed using the screen's four drop-down lists.
Section 8-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ws02-nctc1-e cx-position

Table of Contents