Advertisement

Setting Editing Screens
1,2,3...
4-2-5

Copying Axis Settings

Applicable NC Units
Settings That Can Be
Copied
1,2,3...
54
1. On the (non-parameter) editing screen, select the settings to be cleared,
or designate the range by clicking and dragging.
2. Select Edit/Clear, or right-click and select Clear from the pop-up menu.
Note Under the Edit Menu, Default Clear is enabled when parameter settings are
selected, and Clear is enabled when non-parameter settings are active.
For 2-axis and 4-axis NC Units, data can be copied from one axis to another
axis by selecting the source and destination axes.
4-axis NCs: CS1W-NC413/NC433 and CJ1W-NC413/NC433
2-axis NCs: CS1W-NC213/NC233 and CJ1W-NC213/NC233
The following settings can all be copied using a single procedure.
• Parameters
• Sequences
• Speeds
• Accelerations/Decelerations
• Dwell Times
• Zones
1. Select Edit/Copy Axis
2. Under From, select the axis to be copied from.
The default settings are from X axis to Y axis.
The From axis cannot be the same as the To axis.
Section 4-2