User Parameters Available in Quick Programming Mode

Commonly needed parameters for start-up of the Inverter can be monitored and set in the Quick Programming
Mode. Those parameters are listed in the following tables. All user parameters, including the Quick Program-
ming Parameters can be found in the Advanced Programming Mode as well.
Quick Programming Parameters that are Always Available
Following table shows the parameter that are always available in Quick Programming Mode.
Parame-
ter Num-
ber
Reference
b1-01
source selection
RUN command
b1-02
source selection
Stopping
b1-03
method selec-
tion
PI control mode
b5-01
selection
Acceleration
C1-01
time 1
Deceleration
C1-02
time 1
Frequency ref-
d2-01
erence upper
limit
Frequency ref-
d2-02
erence lower
limit
5-4
Name
Description
Sets the frequency reference input
method.
0: Digital Operator
1: Control circuit terminal (analog input)
2: MEMOBUS communications
3: Option Card
Sets the run command input method
0: Digital Operator
1: Control circuit terminal (digital multi-
function inputs)
2: MEMOBUS communications
3: Option Card
Select stopping method when stop com-
mand is input.
0: Deceleration to stop
1: Coast to stop
2: DC braking stop (Stops faster than
coast to stop, without regenerative
operation.)
3: Coast to stop with timer (Run com-
mands are disregarded during deceler-
ation time.)
0: Disabled
1: Enabled
3: PI control enabled (frequency refer-
ence + PI output)
When PI controller is enabled additional
parameters are available in Quick Pro-
gramming Mode and default values are
changed, refer to the following table.
Sets the acceleration time to accelerate
from 0 Hz to the maximum output fre-
quency.
Sets the deceleration time to decelerate
from the maximum output frequency to
0 Hz.
Sets the frequency reference upper limit
as a percentage of the max. output fre-
quency.
Sets the frequency reference lower limit
as a percentage of the maximum output
frequency.
Change
Setting
Factory
during
Access
Range
Setting
Opera-
Level
tion
0 to 3
1
No
Q
0 to 3
1
No
Q
0 to 3
0
No
Q
0, 1, 3
0
No
A
Yes
Q
0.0 to
10.0
6000.0
sec.
Yes
Q
0.0 to
100.0%
No
A
110.0
0.0 to
0.0%
No
A
110.0
MEMO-
BUS
Register
180H
181H
182H
1A5H
200H
201H
289H
28AH