Omron VARISPEED E7 User Manual page 118

Variable torque frequency inverter
Hide thumbs Also See for VARISPEED E7:
Table of Contents

Advertisement

Param-
eter
Name
Number
Disables or enables the bi-direc-
Bi-directional
tional capabilities of the speed
b3-14
speed search
search function.
selection
0: Disabled
1: Enabled
Timer Function: b4
Param-
eter
Name
Number
Sets the timer function output ON-
delay time (dead time) for the timer
Timer function
b4-01
function input.
ON-delay time
Enabled when the timer function is
set in H1-
Sets the timer function output
OFF-delay time (dead band) for the
Timer function
b4-02
timer function input.
OFF-delay time
Enabled when a timer function is
set in H1-
PI Control: b5
Param-
eter
Name
Number
0: Disabled
PI control mode
1: Enabled
b5-01
selection
3: PI control enabled (frequency
Sets the proportional gain of the PI
Proportional (P)
b5-02
controller. P control is not per-
gain
formed when set 0.00.
Sets the integral time of the PI con-
b5-03 Integral (I) time
troller. I control is not performed
when set to 0.0 sec.
Sets the I control limit as a percent-
b5-04 Integral (I) limit
age of the maximum output fre-
quency.
Sets the limit after PI control as a
b5-06 PI limit
percentage of the maximum output
frequency.
Sets the offset after PI control as a
b5-07 PI offset
percentage of the maximum output
frequency.
Sets the time constant for low pass
PI delay time
b5-08
filter of the PI control output.
constant
Usually not necessary to set.
Selects forward/reverse direction
PI output charac-
for PI output.
b5-09
teristics selection
0: PI output is forward.
1: PI output is reversed.
b5-10 PI output gain
Sets output gain.
Description
Description
and H2-
.
and H2-
Description
reference + PI output)
Change
Setting
Factory
during
Access
Range
Setting
Opera-
Level
tion
0 or 1
1
No
Change
Setting
Factory
during
Access
Range
Setting
Opera-
Level
tion
0.0 to
0.0 sec.
No
A
3000.0
0.0 to
0.0 sec.
No
A
3000.0
Change
Setting
Factory
during
Access
Range
Setting
Opera-
Level
tion
0, 1, 3
0
No
Q
0.00
to
1.00
Yes
A
25.00
0.0 to
1.0 sec.
Yes
A
360.0
0.0 to
100.0%
Yes
A
100.0
0.0 to
100.0%
Yes
A
100.0
-100.0
to
0.0%
Yes
A
+100.0
0.00 to
0.00
Yes
A
10.00
sec.
0 or 1
0
No
A
0.0 to
1.0
No
A
25.0
User Parameter Tables
MEMO-
BUS
Page
Register
A
19EH
6-39
MEMO-
BUS
Page
Register
1A3H
6-86
1A4H
6-86
MEMO-
BUS
Page
Register
1A5H
6-87
*1
1A6H
6-87
*1
1A7H
6-87
1A8H
6-87
1AAH
6-87
1ABH
6-87
1ACH
6-87
1ADH
6-87
1AEH
6-87
5-11

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents