Download Print this page
Omron CIMR-E7Z Datasheet
Omron CIMR-E7Z Datasheet

Omron CIMR-E7Z Datasheet

Frequency inverter for pumps and fans
Hide thumbs Also See for CIMR-E7Z:

Advertisement

Quick Links

CIMR-E7Z
Varispeed E7
Frequency inverter for pumps and fans
• Energy saving function.
• Advanced PID controller with dedicated HVAC
functions.
• 12 pulse operation for harmonics reduction.
• Speed search.
• Standard RS-485 communication - MODBUS.
• Optional network cards
(DeviceNet, PROFIBUS, CANOpen, LONWORKS).
• CE, UL, and cUL marked and Germanischer Lloyds
approval.
• Embedded OMRON PLC functionality with
PLC option card
• PC configuration tool CX-drive.
• CE, UL, and cUL marked and Lloyds approval.
E7IP54
• Robust metal chassis.
• LCD operator.
• Built in RFI filter.
Customized software
• The inverter software can be customized to meet
specific application. Examples:
• Pump sequencer (S-8801).
*For detailed information please refer to CASE software section.
Ratings
• 200 V Class 0.4 to 110 kW.
• 400 V Class 0.4 to 300 kW.

System configuration

3G3IV-PCN329-E
Inverter to PC cable
Line filter
* E7 IP54 types are built-in filter inverters.
Communication card
Varispeed E7
CX-Drive
*
see note
JVOP-160 OY
JVOP-161-OY
Digital operator
Digital operator
(LCD display)
(LED display)
Varispeed E7
PLC option card
3G3IV-PCN126/326
Digital operator
extension cable
Braking accessories
LKEB_ braking
CDBR_B
resistor unit
braking unit
309

Advertisement

loading

Summary of Contents for Omron CIMR-E7Z

  • Page 1: System Configuration

    • Speed search. • Standard RS-485 communication - MODBUS. • Optional network cards (DeviceNet, PROFIBUS, CANOpen, LONWORKS). • CE, UL, and cUL marked and Germanischer Lloyds approval. • Embedded OMRON PLC functionality with PLC option card • PC configuration tool CX-drive.
  • Page 2 400 V class Model CIMR-E7ZZ@ 40P4 40P7 41P5 42P2 43P7 44P0 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300 IP54 model: CIMR-E7Z --- 47P52 40112 40152 40182 40222 40302 40372 40452 40552 --- Max.
  • Page 3 Available as standard (IEC IP00) enclosed type Model CIMR-E7Z 40P4 40P7 41P5 42P2 43P7 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300 Enclosed type Available as standard Available for option...
  • Page 4 Voltage output kW CIMR-E7Z@ weight kg method ---- 0.75 ---- ---- ---- ---- Not available, please use the IP20 type removing the upper and lower cover ---- ---- ---- ---- 18.5 ---- 2022 0 2030 0 2037 0 2045 0 12.5...
  • Page 5 Enclosed type (IEC IP20) E7Z 20P41 to E7Z25P51 E7Z 27P51 to E7Z20181 E7Z 20221 to E7Z20751 E7Z40P41 to E7Z45P51 E7Z47P51 to E7Z40181 E7Z40221 to E7Z41601 Fig 1 Fig 2 Fig 3 Dimensions in mm Max. applicable motor Inverter Approx. Cooling...
  • Page 6 Field bus Door (option) Mounting holes Cable entry plate Accessories Following parts are delivered in the package with the inverter Part name Cable gland (for input)* Cable gland (for motor output)* Cable gland (for control)* Cable gland (for fieldbus)* Door key...
  • Page 7 3G3RV-PFI2100-SE 3G3RV-PFI3010-SE 3G3RV-PFI3018-SE 3G3RV-PFI3021-SE 3G3RV-PFI3035-SE 400 V 3G3RV-PFI3060-SE 32.5 12.0 3G3RV-PFI3410-SE 12.0 3G3RV-PFI3600-SE 3G3RV-PFI3800-SE Flat filters are not possible to be mounted as footprint filters. Bookform filters Dimensions Model 3G3RV-PFI2130-SE 200 V 3G3RV-PFI2160-SE 3G3RV-PFI2200-SE 3G3RV-PFI3070-SE 3G3RV-PFI3100-SE 400 V 3G3RV-PFI3130-SE 3G3RV-PFI3170-SE...
  • Page 8 Braking unit dimensions Model CDBR-2015 B, -2022 B, -4030B, -4045 B Model CDBR-2110 B 4-M6 MTG holes 4-M4 MTG holes 66.5 Main circuit terminal Lead wire inlet (28 dia. rubber bush) 2-lead wire inlet (35 dia. rubber bush) 114.5 30 or...
  • Page 9 Heatsink external mounting attachment The Varispeed E7 inverters under the 200/400 V class 18.5 kW or less need this attachment for mounting the heatsink externally. This attachment expands the outer dimensions of the width and height of the inverter. (Attachment is not required for inverters of 22 kW or more.)
  • Page 10: Standard Connections

    (0 to 10 V, 2 mA) Analog input power supply [Default: Output power, 0 to 10 V] -15 V, 20 mA Terminating resistance MEMOBUS communication RS-485/422 Twisted-pair Shielded wires shielded wires *E7 IP54 types has RFI filter included as standard Frequency inverters...
  • Page 11: Main Circuit

    - /l : 200 to 220 VAC 50 Hz, 200 to 230 VAC 60 Hz (A transformer is required for 230 V 50 Hz or 240 V 50/60 Hz power supply.) Cooling fan power supply r/l - 200 / l...
  • Page 12: Control Circuit

    – Note: 1.The default settings are given for terminals S3 to S7. For a 3-wire sequence, the default settings are a 3-wire sequence for S5, multi-step speed setting 1 for S6 and multi-step speed setting 2 for S7. 2.Do not use this power supply for supplying any external equipment.
  • Page 13 114 158 172 208 259 317 360 415 495 575 671 853 100 114 137 153 232 Inside unit 115 148 161 209 307 410 498 634 725 995 114 131 169 197 228 295 339 393 460 527 815 Total heat loss...
  • Page 14 Connections for braking units Braking resistor overload Braking resistor overload Relay trip contact relay trip contact (thermal relay trip contact) (thermal relay trip contact) Braking Braking resistor resistor unit unit * Varispeed E7 Braking unit 2* Braking unit 1 Cooling fin overheat contact...
  • Page 15 18.5 18.5 22 to 110 Built-in 22 to 300 Built-in Fuse installation To protect the inverter, it is recommended to use semiconductor fuses as shown in the table below FUSE Inverter type FUSE Voltage (V) Current (A) t (A Inverter type...
  • Page 16 (LED display) Line Filter Braking accessories see note LKEB_ braking CDBR_B resistor unit braking unit Varispeed E7 * E7 IP54 types are built-in filter inverters. Communication card PLC option card Varispeed E7 200 V 400 V Specifications Model Specifications Model IP20 0.55 Kw...
  • Page 17 CIMR-E7Z4055 CIMR-E7Z2090 3G3RV-PFI3170-SE A, 100 m CIMR-E7Z4075 CIMR-E7Z2110 3G3RV-PFI3600-SE A, 100 m 11.0 CIMR-E7Z4090 3G3RV-PFI3200-SE A, 100 m Varispeed E7 is a built-in filter inverter. CIMR-E7Z4110 CIMR-E7Z4132 3G3RV-PFI3410-SE A, 100 m CIMR-E7Z4160 CIMR-E7Z4185 3G3RV-PFI3600-SE A, 100 m 11,0 CIMR-E7Z4220 3G3RV-PFI3800-SE A, 100 m 31.0...
  • Page 18 B Communication cards Type Model Description Function • Used for running or stopping the inverter, setting or referencing parameters, and monitoring out- 3G3RV-PDRT2 DeviceNet option card put frequency, output current, or similar items through DeviceNet communication with the host controller.
  • Page 19 For an application with large regenerative power such as hoisting, the braking torque or other items may exceed the capacity of a braking unit with a braking resistor in a standard combination (can result in capacity overload). Contact your OMRON representatives when the braking torque or any other item exceeds the values in the table.
  • Page 20 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. Cat. No. I21E-EN-02 Frequency inverters...

This manual is also suitable for: