Sign In
Upload
Manuals
Brands
Omron Manuals
Inverter
CIMR-E7Z4160
Omron CIMR-E7Z4160 Manuals
Manuals and User Guides for Omron CIMR-E7Z4160. We have
1
Omron CIMR-E7Z4160 manual available for free PDF download: User Manual
OMRON CIMR-E7Z4160 User Manual (321 pages)
Variable Torque Frequency Inverter
Brand:
OMRON
| Category:
Inverter
| Size: 6.97 MB
Table of Contents
Table of Contents
2
Warnings
8
Safety Precautions and Instructions for Use
9
EMC Compatibility
11
Line Filters
13
Registered Trademarks
16
1 Handling Inverters
18
Varispeed E7 Introduction
19
Varispeed E7 Applications
19
Varispeed E7 Models
19
Confirmations Upon Delivery
21
Checks
21
Nameplate Information
21
Inverter Software Version
22
Component Names
23
Exterior and Mounting Dimensions
26
IP00 Inverters
26
NEMA 1 / IP20 Inverters
27
IP54 Inverters
27
Checking and Controlling the Installation Site
30
Installation Site
30
Controlling the Ambient Temperature
30
Protecting the IP00 or NEMA 1 Inverter from Foreign Matter
30
Additional Installation Precautions for the IP54 Inverters
31
Keeping the IP54 Protection
31
Installation Orientation and Space
32
Accessing the Inverter Terminals
33
Removing the Terminal Cover (IP00 and NEMA 1 / IP20 Inverters)
33
Attaching the Terminal Cover
33
Opening the Door (IP54 Inverters)
34
Closing the Door (IP54 Inverters)
34
Removing/Attaching the Digital Operator and
35
Inverters of 18.5 Kw or Less
35
Inverters of 22 Kw or more
37
2 Wiring
38
Connection Diagrams
39
Circuit Descriptions
41
Terminal Block Configuration
42
Wiring Main Circuit Terminals
44
Applicable Wire Sizes and Crimp Terminals
44
Main Circuit Terminal Functions
52
Main Circuit Configurations
53
Standard Connection Diagrams
55
Wiring the Main Circuits
57
Wiring Control Circuit Terminals
64
Wire Sizes
64
Control Circuit Terminal Functions
68
Control Circuit Terminal Connections
72
Control Circuit Wiring Precautions
73
Wiring Check
74
Checks
74
Installing and Wiring Option Cards
75
Option Card Models
75
Installation in IP00 and NEMA 1 / IP20 Inverters
75
Installation in IP54 Inverters
76
3 Digital Operator and Modes
78
Digital Operator
79
Digital Operator Display
79
Digital Operator Keys
80
Modes
82
Inverter Modes
82
Switching Modes
83
Drive Mode
85
Quick Programming Mode
86
Advanced Programming Mode
88
Verify Mode
92
Autotuning Mode
94
4 Trial Operation
96
Trial Operation Procedure
97
Trial Operation
98
Application Confirmation
98
Setting the Power Supply Voltage Jumper (400 V Class Inverters of 75 Kw or Higher)
98
Power on
98
Checking the Display Status
99
Basic Settings
100
Selecting the V/F Pattern
102
Autotuning
102
Application Settings
104
No-Load Operation
104
Loaded Operation
104
Check and Recording User Parameters
105
Adjustment Suggestions
106
5 User Parameters
108
User Parameter Descriptions
109
Description of User Parameter Tables
109
Digital Operation Display Functions and Levels
110
User Parameters Available in Quick Programming Mode
111
User Parameter Tables
113
Setup Settings: a
113
Application Parameters: B
115
Tuning Parameters: C
122
Reference Parameters: D
125
Motor Parameters: E
127
Option Parameters: F
129
Terminal Function Parameters: H
130
Protection Function Parameters: L
136
Special Adjustments: N
142
Digital Operator Parameters: O
143
Motor Autotuning: T
147
Monitor Parameters: U
148
Setting Values that Change with the V/F Pattern Selection (E1-03)
153
Factory Settings that Change with the Inverter Capacity (O2-04)
154
6 Parameter Settings by Function
158
Carrier Frequency Selection
159
Setting the Carrier Frequency
159
Frequency Reference
162
Selecting the Frequency Reference Source
162
Using Multi-Step Speed Operation
164
Run Command
166
Selecting the Run Command Source
166
Stopping Methods
168
Selecting the Stopping Method When a Stop Command Is Input
168
Using the DC Injection Brake
170
Using an Emergency Stop
171
Acceleration and Deceleration Characteristics
172
Setting Acceleration and Deceleration Times
172
Preventing the Motor from Stalling During Acceleration (Stall Prevention During Acceleration Function)
174
Stall Prevention During Deceleration Function
176
Adjusting Frequency References
178
Adjusting Analog Frequency References
178
Jump Frequency Function (Operation Avoiding Resonance)
180
Speed Limit
181
(Frequency Reference Limit Function)
181
Limiting Maximum Output Frequency
181
Limiting Minimum Frequency
181
Speed Limit (Frequency Reference Limit Function)
181
Frequency Detection
182
Speed Agreement Function
182
Improved Operating Performance
184
Torque Compensation for Sufficient Torque at Start and Low-Speed Operation
184
Hunting Prevention Function
185
Machine Protection
186
Preventing Motor Stalling During Operation
186
Load Detection
187
Motor Overload Protection
190
Motor Overheat Protection Using PTC Thermistor Inputs
192
Limiting Motor Rotation Direction and Output Phase Rotation
194
Automatic Restart
195
Restarting Automatically after Momentary Power Loss
195
Speed Search
196
Continuing Operation at Constant Speed When Frequency Reference Is Lost
201
Restarting Operation after Transient Fault (Auto Restart Function)
202
Inverter Protection
204
Inverter Overheat Protection
204
Input Phase Loss Detection Level
205
Ground Fault Protection
205
Cooling Fan Control
206
Setting the Ambient Temperature
206
OL2 Characteristics at Low Speed
207
Soft CLA Selection
208
Input Terminal Functions
209
Temporarily Switching Operation between Digital Operator and Control Circuit Terminals
209
Blocking the Inverter Output (Baseblock Command)
210
Multifunction Analog Input A2 Disable/Enable
210
Drive Enable/Disable
211
Bypass Drive Enable
211
Stopping Acceleration and Deceleration (Acceleration/Deceleration Ramp Hold)
211
Raising and Lowering Frequency References Using Digital Input Signals (UP/DOWN)
212
Trim Control Function
215
Analog Frequency Reference Sample/Hold
216
Switching Operation Source to Communication Option Card
217
Switching Operation Source to MEMOBUS Communication
217
AUTO/HAND Mode Switching by Digital Input
218
Jog Frequency Operation Without Forward and Reverse Commands (FJOG/RJOG)
219
Stopping the Inverter on External Faults (External Fault Function)
220
Output Terminal Functions
221
Monitor Parameters
224
Using the Analog Monitor Parameters
224
Individual Functions
226
Using MEMOBUS Communications
226
Communications Connection Terminal
227
Related Parameters
228
Message Format
229
Inverter Fault Codes
240
Enter Command
241
Communications Error Codes
241
Using the Timer Function
243
Using PI Control
244
Energy-Saving
255
Setting Motor Parameters
256
Setting the V/F Pattern
257
Motor Preheat Function
263
Emergency Override Function
265
High Slip Braking
266
Digital Operator Functions
267
Setting Digital Operator Functions
267
Copying Parameters
270
Prohibiting Writing Parameters from the Digital Operator
274
Setting a Password
274
Displaying User-Set Parameters Only
275
7 Troubleshooting
276
Protective and Diagnostic Functions
277
Fault Detection
277
Alarm Detection
283
Operator Programming Errors
286
Autotuning Faults
288
Digital Operator Copy Function Faults
288
Troubleshooting
290
If Parameters Cannot be Set
290
If the Motor Does Not Operate
291
If the Direction of the Motor Rotation Is Reversed
292
If the Motor Does Not Put out Torque or if Acceleration Is Slow
292
If the Motor Operates at Higher Speed than the Frequency Reference
292
If Motor Deceleration Is Slow
293
If the Motor Overheats
293
If Peripheral Devices Like Plcs or Other Are Influenced
294
By the Starting or Running Inverter 7
294
If the Earth Leakage Breaker Operates When a RUN Command Is Input
294
If There Is Mechanical Oscillation
294
If the Motor Rotates Even When Inverter Output Is Stopped
295
If OV (Overvoltage) or OC (Overcurrent) Is Detected When a Fan Is Started, or a Fan Stalls
295
If Output Frequency Does Not Rise to Frequency Reference
295
8 Maintenance and Inspection
296
Maintenance and Inspection
297
Periodic Inspection
297
Periodic Maintenance of Parts
299
Cooling Fan Replacement Outline
300
Removing and Mounting the Control Circuit Terminal Card
302
9 Specifications
304
Standard Inverter Specifications
305
Specifications by Model
305
Common Specifications
308
10 Appendix
310
Inverter Application Precautions
311
Selection
311
Installation
311
Settings
312
Handling
312
Motor Application Precautions
313
Using the Inverter for an Existing Standard Motor
313
Using the Inverter for Special Motors
314
Power Transmission Mechanism (Speed Reducers, Belts and Chains)
314
User Parameters
315
Advertisement
Advertisement
Related Products
Omron CIMR-E7Z41P5
Omron CIMR-E7Z4110
Omron CIMR-E7Z4132
Omron CIMR-E7Z4185
Omron CIMR-E7Z40P4
Omron CIMR-E7Z40P7
Omron CIMR-E7Z4011
Omron CIMR-E7Z4015
Omron CIMR-E7Z4022
Omron CIMR-E7Z4045
Omron Categories
Blood Pressure Monitor
Controller
Accessories
Switch
Inverter
More Omron Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL