3 .0 Specifications

Dimensions (W x D x H)
Maximum Speed
Maximum RCF
Maximum Volume
Timer
Admissible Sample Density
Electrical/Fuse Rating
C2500
C2500-230V
C2500-100V
Temperature Range
Protection Class
The Labnet Prism™ microcentrifuge is designed to be safe at least when operated under the following conditions:
Indoor use only

Altitude up to 2,000 meters

Pollution Degree 2

Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate
the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in
a commercial environment. The equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the user manual, may cause harmful interference to radio communications. Operation of equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct the interference.
CAUTION: This equipment is not intended for use in residential environments and may not provide adequate protection
to radio reception in such environments.
This ISM device complies with Canadian ICES-001.
Cet appareil ISM est conforme à la norme NMB-001 du Canada.

4.0 Package Contents

Labnet Prism microcentrifuge

Standard angle rotor (Cat. No. 24D-RTR)

Rotor removal tool

Power cord

Instruction manual


5.0 Installation

The centrifuge should be installed on a rigid, even surface such as a stable laboratory bench, countertop, etc. To guarantee
sufficient ventilation, ensure that the centrifuge has at least 6 inches (15 cm) of free space on all sides, including the rear. The
centrifuge should not be located in areas subject to excessive heat such as in direct sunlight or near radiators or the exhaust of a
compressor, as a buildup of heat may occur within the chamber.
Before operating the centrifuge, check that the power source (electrical outlet on the wall) corresponds to that on the
manufacturer's rating label, then connect the power cord to the centrifuge and the power source.
2
|
LABNET PRISM MICROCENTRIFUGE
10.1 x 14.2 x 7.6 in. (25.7 x 36.0 x 19.4 cm)
15,000 rpm
21,200 x g
24 x 2.2 mL
0.5 to 99 minutes or continuous
1.2 kg/dm
3
120V~, 50/60 Hz, 250W, 3.4A
230V~, 50/60 Hz, 200W, 1.4A
100V~, 50/60 Hz, 230W, 3.5A
5°C to 40°C (up to 80% RH at 31°C, decreasing linearly to 50% RH at 40°C)
IP21