4 .0 Technical Specifications
Dimensions (W x D x H)
Maximum Speed
Maximum RCF
Maximum Volume
Admissible Density
Electrical/Fuse Rating
C2400
C2400-100V
C2400-230V
Temperature Range
Protection Class
The Labnet Spectrafuge™ 24D Microcentrifuge is designed to be safe at least when operated under the following conditions:
Indoor use only
Altitude up to 2,000 meters
Pollution degree 2
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate
the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in
a commercial environment. The equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the user manual, may cause harmful interference to radio communications. Operation of equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct the interference.
CAUTION: This equipment is not intended for use in residential environments and may not provide adequate protection
to radio reception in such environments.
This ISM device complies with Canadian ICES-001.
Cet appareil ISM est conforme à la norme NMB-001 du Canada.
5.0 Package Contents
Spectrafuge 24D microcentrifuge
Angle rotor for 24 x 1.5/2.0 mL tubes
Rotor removal tool
Power cord
Instruction manual
6.0 Installation
6.1 Unpacking the Centrifuge
Before unpacking the centrifuge, inspect the outside of the carton for any shipping damage. The centrifuge is delivered in a carton
with protective cushions. Remove the centrifuge from the carton. Retain the carton and cushions until it has been established that the
centrifuge is working properly. Inspect the centrifuge for any visible signs of shipping damage. Shipping damage is the responsibility
of the transportation carrier. Any claims for damage must be filed within 48 hours. The accessories supplied with the centrifuge
should be kept with the instruction manual near the centrifuge's place of installation.
6.2 Required Space
The centrifuge should be installed on a rigid, even surface such as a stable laboratory bench, cabinet, etc. To guarantee sufficient
ventilation, ensure that the centrifuge has at least 15 cm (6 inches) of free space on all sides, including the rear. The centrifuge should
not be located in areas subject to excessive heat such as in direct sunlight or near radiators or the exhaust of a compressor, as a
buildup of heat may occur within the chamber.
2
|
LABNET SPECTRAFUGE 24D MICROCENTRIFUGE
9.3 x 11.5 x 8.5 in. (23.5 x 29.2 x 21.6 cm)
13,300 rpm
16,300 x g
24 x 1.5/2.0 mL
1.2 kg/dm
3
120V~, 50/60 Hz, 200W, 2.6A
100V~, 50/60 Hz, 190W, 2.7A
230V~, 50/60 Hz, 170W, 1.2A
5°C to 40°C (up to 80% RH at 31°C, decreasing linearly to 50% RH at 40°C)
IP21