Labnet Spectrafuge™ 16M
Microcentrifuge
Instruction Manual
Catalog Numbers:
C0160
C0160-230V

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Spectrafuge 16M and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Labnet Spectrafuge 16M

  • Page 1 Labnet Spectrafuge™ 16M Microcentrifuge Instruction Manual Catalog Numbers: C0160 C0160-230V...
  • Page 2: Table Of Contents

    Table of Contents 1.0 Introduction .........1 9.0 Service and Maintenance .
  • Page 3: Introduction

    The Labnet Spectrafuge™ 16M Microcentrifuge is a small benchtop centrifuge designed for separation of various research samples. The motor is brushless and requires no routine maintenance. The Spectrafuge 16M is supplied with an 18 x 1.5 mL rotor for micro- samples.
  • Page 4: Specifications

    230V ± 10%, 50/60 Hz, 0.7A/1.25AT Operation conditions 5°C to 40°C, up to 80% RH, non-condensing The Labnet Spectrafuge 16M Microcentrifuge is designed to be safe at least when operated under the following conditions: Indoor use only  Altitude up to 2,000 meters ...
  • Page 5: Rotors And Rotor Maintenance

    7.0 Rotors and Rotor Maintenance 7.1 Rotors and accessories The following accessories are available for the Spectrafuge 16M Microcentrifuge. Tube Measurement Max. Speed Centrifuging RCF (g-Value) Cat. No. (mm) (rpm) Radius (cm) (x g) Angle rotor for 18 x 1.5 mL tubes...
  • Page 6: Overloading Rotors

    The speed (rpm) can be selected to 14,000 rpm using the Speed knob. The scale is directly proportional to the speed – a setting of 9 corresponds to 9,000 rpm, a setting of 13 corresponds to a speed of 13,000 rpm, etc. LABNET SPECTRAFUGE 16M MICROCENTRIFUGE...
  • Page 7: Selection Of Operating Time And Momentary

    8.5 Selection of operating time and momentary operation Operation of the centrifuge begins when the Time knob is turned clockwise to set a run time. For run times less than 5 minutes, turn the knob clockwise past the halfway point and then counterclockwise to the desired time. For run times longer than 5 minutes, turn the knob clockwise to the desired time.
  • Page 8: Determination Of G-Values

    The RCF value is the point where the line crosses the center column. The nomogram is based on the formula: RCF = (11/17 x 10 ) RN where: R = Radius in mm from centrifuge spindle to point in tube bottom N = Speed of spindle in RPM LABNET SPECTRAFUGE 16M MICROCENTRIFUGE...
  • Page 9: Limited Warranty

    11.0 Limited Warranty Corning Incorporated (Corning) warrants that this product will be free from defects in material and workmanship for a period of one (1) year from date of purchase. CORNING DISCLAIMS ALL OTHER WARRANTIES WHETHER EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE.
  • Page 10 To request certificates, please contact us at www.labnetlink.com. Warranty/Disclaimer: Unless otherwise specified, all products are for research use or general laboratory use only.* Not intended for use in diagnostic or therapeutic procedures. Not for use in humans. These products are not intended to mitigate the presence of microorganisms on surfaces or in the environment, where such organisms can be deleterious to humans or the environment.