Omron CX-INTEGRATOR V2 - 12-2009 Operation Manual page 37

Table of Contents

Advertisement

Item
Connecting to the
Either of the following can be used.
Relay PLC
Serial
communications
FINS network
communications
*1:
*2:
Direction connection is possible to any of the following serial ports on a
CS/CJ/CP-series PLC.
• CPU Unit USB port (Toolbus)
• CPU Unit peripheral port (Toolbus or Host Link)
• CPU Unit RS-232C port (Toolbus or Host Link)
• A CP-series CPU Unit is connected to the USB port using a
commercially available USB cable (type B – type A).
• Serial Communications Board or Serial Communications Unit RS-232C
port or RS-422A/485 port (Host Link) (See note.)
Note: For a CP-series CPU Unit, connect to a CP1W-CIF01/11 Option
Board (Toolbus or Host Link).
Direct connection is possible to any of the following serial ports on an
NSJ-series NSJ Controller.
• RS-232C port A (Toolbus) on NSJ Controller
• RS-232C port B (Toolbus) on NSJ Controller
• USB port on NSJ Controller
Note: Automatic online connection is possible for serial communications
ports. (The user does not have to set the computer communications
settings.) The communications settings will be automatically set to
those of the PLC. Connection is possible to a serial port on the CPU
Unit, a Serial Communications Board, or a Serial Communications
Unit. For PLC serial ports, however, only the Toolbus or Host Link
serial communications modes can be used and the baud rate must
be 9600, 19200, 38400, or 115200 bits/s.
Direction connection is possible through any of the following networks on
a CS/CJ-series PLC or NSJ-series NSJ Controller.
• Ethernet (Ethernet, Ethernet FINS/TCP, or FinsGateway
• Controller Link (Controller Link
• SYSMAC LINK (SYSMAC LINK
When running the CX-Integrator on Windows Vista or Windows 7, an online connection
will not be possible to the relay PLC even if communications for one of these networks is
selected.
If FinsGateway is selected, connection will not be possible to a DeviceNet, CompoNet,
or CompoWay/F network. To connect to any of these networks, use Ethernet, Ethernet
(FINS/TCP), Controller Link, or SYSMAC LINK instead of FinsGateway.
1-2
1-2-1
CX-Integrator Specifications
Specification
*1
or FinsGateway
*1
or FinsGateway
Specifications
*2
)
*2
)
*2
)
1-9