Omron CX-INTEGRATOR V2 - 12-2009 Operation Manual page 107

Table of Contents

Advertisement

Note 1: With a CJ2H-CPU6@-EIP CPU Unit, connecting to an Ethernet network is not
possible from the built-in EtherNet/IP port or an EtherNet/IP Unit port if the
network connection is set for EtherNet/IP. Always set Ethernet or Ethernet
(FINS/TCP) to connect to an Ethernet network. In addition, connection is
impossible when "USB" is selected in the network settings. Select "Toolbus
(USB port)".
Note 2: CJ2 CPU Unit cannot select this network type.
Note 3: When connecting online with a SYSMAC CS1 Board, specify one of the device
types in parentheses. CS1 Board can be selected as the network type only
when one of these device types is selected.
Note 4: The following functions cannot be used when running the CX-Integrator on
Windows Vista or Windows 7.
- Online connections to PLCs on Controller Link networks are not possible
through a Controller Link Support Board when Controller Link is selected
as the network type.
- Online connections to PLCs on SYSMAC LINK networks are not
possible through a SYSMAC LINK Support Board when SYSMAC LINK
is selected as the network type.
- Online connections to PLCs on SYSMAC NET networks are not possible
through a SYSMAC NET Support Board when SYSMAC NET is selected
as the network type.
- Online connections to CS1 Boards in computers are not possible when
"CS1 board" is selected as the network type.
- Online connections to SYSMAC Boards in computers are not possible
when "SYSMAC Board" is selected as the network type.
- Online connections to PLCs on the network are not possible when
FinsGateway is selected as the network type.
Click the Settings Button to display the Network Settings Dialog Box for each type of
network. Details are described here for Toolbus, SYSMAC WAY, and Ethernet. Refer to
the CX-Programmer Operation Manual (Cat. No. W446) for other methods.
Toolbus
Click the Driver Tab and set the following settings as required.
Port Name:
Baud Rate:
Baud Rate Auto-Detect: Clear this selection to connect with the baud rate set on the
2-2
Connecting Online to the Relay PLC
Select the computer's COM port from the drop-down list.
Select the baud rate (bits/s) from the drop-down list.
computer, ignoring the baud rate of the serial port on the CPU
Unit. To disable automatic detection of the baud rate, the DIP
switch on the CPU Unit must be set as follows:
2-2-2
Procedures
2-15