Connection area
The connection area divider separates the high-voltage conductors (DC and AC)
divider
from the signal lines. To make it easier to reach the connection area, the divider
can be removed for the connection work, and must be re-inserted.
Ground elec-
trode terminal
24

Connection area divider

AC conduit connection (Ø ½ - 1 inch / 13 - 25 mm)
Ground spike conduit connection (Ø 5/8 inch / 16 mm)
DatCom conduit connection (Ø ½ - ¾ inch / 13 - 19 mm)
Data communication area conduit connection
Drain valve
DC conduit connection (Ø ½ - 1 inch / 13 - 25 mm)
(1)
Integrated cable duct
(2)
Recesses for removing the con-
nection area divider
(3)
Snap tabs for locking/unlocking
(4)
Defined breaking point for the
DatCom connection
The integrated cable duct (1) allows for
the lines to be laid from one area of
the inverter to the other. As a result,
multiple inverters can be easily in-
stalled next to each other.
The ground electrode terminal
provides the option of grounding addi-
tional components, such as:
-
AC cable
-
Module mounting system
-
Ground spike