Installation

NOTE!
All loads that are to be supplied via the OP terminal must be protected by
means of a ground fault circuit interrupter.
In order to ensure the ground fault circuit interrupter operates properly, a con-
nection must be established between the neutral conductor N' (OP) and equip-
ment grounding (GND).
Wiring proposal recommended by Fronius, see page 115.
1
2
Danger from faulty or incorrect bores.
This may lead to injuries to the eyes and hands as a result of flying debris and
sharp edges, as well as damage to the inverter.
60
CAUTION!
When drilling, wear suitable protective goggles.
Only use a step drill when drilling.
Ensure that nothing on the inside of the device is damaged (e.g., the connec-
tion block).
Adapt the diameter of the bore to match the corresponding connection.
Deburr the bores using a suitable tool.
Remove the drilling residues from the inverter.
Turn off the automatic circuit breaker.
Set the DC disconnector to the "Off"
switch position.
Loosen the five screws of the connec-
tion area cover by rotating them 180°
to the left using a screwdriver (TX20).
Remove the connection area cover
from the device.