Technical Data; Technical Data For Fronius Primo Gen24 7.7 - Fronius Primo GEN24 208-240 Operating Instructions Manual

Hide thumbs Also See for Primo GEN24 208-240:
Table of Contents

Advertisement

Technical data

Technical data
DC input data
for Fronius
MPP voltage range
Primo GEN24 7.7
208 - 240
Max. input voltage
at 1000 W/m²/14 °F in an open circuit
Min. input voltage
Start-up input voltage
Nominal PV power
Nominal input voltage
Max. PV array power
Nominal input current
Max. input current
PV 1
PV 2
Max. short circuit current for module array (I
PV 1
PV 2
Max. total short circuit current for module array
(I
Max. continuous utility backfeed current
AC output data
Max. output power
Max. output power at
+140 °F (60 °C) V min /
V max
Nominal AC voltage
Voltage trip limit accuracy
Max. continuous output
current at V
Output overcurrent pro-
tection
Phases
104
+ I
= I
SC PV1
SC PV2
SC max
nom
at 208 V
at 220 V
at 240 V
at 208 V
at 220 V
at 240 V
at 208 V
at 220 V
at 240 V
at 208 V
at 220 V
at 240 V
SC PV
)
1)
at 208 V
at 220 V
at 240 V
at 208 V
at 220 V
at 240 V
at 208 V
at 220 V
at 240 V
at 208 V
at 220 V
at 240 V
260 - 480 V
7920 W
7920 W
7920 W
11520 W
11520 W
11520 W
)
41.25 A
77.25 A
7680 W
7680 W
7680 W
7680 W
7680 W
7680 W
208 V/220 V/240 V
1% of nominal value
600 V
65 V
65 V
365 V
365 V
385 V
21.7 A
21.7 A
20.6 A
22 A
22 A
36 A
0.0 A
36.9 A
34.9 A
32.0 A
50.0 A
45.0 A
40.0 A
1