Connection area
The connection area divider separates the high-voltage conductors (DC and AC)
divider
from the signal lines. To make it easier to reach the connection area, the divider
can be removed for the connection work, and must be re-inserted.
Ground elec-
trode terminal
Connection area divider
10 x DC cable glands
Optional cable gland (M16)
Optional cable gland (M16 - M20)
Optional cable gland (M16 - M32)
Optional cable gland (M16 - M25)
(1)
Integrated cable duct
(2)
Recesses for removing the con-
nection area divider
(3)
Snap tabs for locking/unlocking
(4)
Defined breaking point for the
Datcom connection
The integrated cable duct (1) allows for
the lines to be laid from one area of
the inverter to the other. As a result,
multiple inverters can be easily in-
stalled next to each other.
The ground electrode terminal
lows additional components to be
earthed, such as:
-
AC cable
-
Module mounting system
-
Ground rod
al-