(9)
(10)
(11)
(12)
(13)
(14)
Connection area
The connection area divider separates the high-voltage conductors (DC and AC) from
divider
the signal lines. To make it easier to reach the connection area, the divider can be
removed for the connection work, and must be re-inserted.
Ground electrode
terminal
Connection area divider
10 x DC cable glands
Optional cable gland (M16)
Optional cable gland (M16 - M20)
Optional cable gland (M16 - M32)
Optional cable gland (M16 - M25)
(1)
Integrated cable duct
(2)
Recesses for removing the con-
nection area divider
(3)
Snap tabs for locking/unlocking
(4)
Defined breaking point for the Dat-
com connection
The integrated cable duct (1) allows for the
lines to be laid from one area of the
inverter to the other. As a result, multiple
inverters can be easily installed next to
each other.
The ground electrode terminal
additional components to be earthed, such
as:
-
AC cable
-
Module mounting system
-
Ground rod
Allows
27