Type 4X
13123 ft
4001 m
0 ft / m
38
The inverter is suitable for outdoor installation.
When properly installed, the inverter has a Type 4X protection
class, is not susceptible to spraying water on any side and can
also be operated in moist environments.
In order to keep inverter heating as low as possible, do not ex-
pose the inverter to direct sunlight. The inverter should be in-
stalled in a protected location, e.g., near the PV modules or un-
der an overhanging roof.
13123 ft
4001 m
IMPORTANT! The inverter must not be installed or operated at
more than 13,123 ft / 4001 m above sea level.
Do not install the inverter:
-
Where it may be exposed to ammonia, corrosive gases, acids
or salts (e.g., fertilizer storage areas, vent openings for live-
stock stables, chemical plants, tanneries, etc.)
During certain operating phases the inverter may produce a
slight noise. For this reason it should not be installed in an occu-
pied living area.
Do not install the inverter in:
-
Areas where there is an increased risk of accidents from
farm animals (horses, cattle, sheep, pigs, etc.)
-
Stables or adjoining areas
-
Storage areas for hay, straw, chaff, animal feed, fertilizers,
etc.
The inverter is essentially designed to be dustproof (Type 4X). In
areas of high dust accumulation, dust deposits may collect on
the cooling surfaces, and thus impair the thermal performance.
Regular cleaning is required in this case; see the chapter headed
Operation in dusty environments
commend not installing the inverter in areas and environments
with high dust accumulation.
Do not install the inverter in:
-
Greenhouses
-
Storage or processing areas for fruit, vegetables or viticul-
ture products
-
Areas used in the preparation of grain, green fodder or an-
imal feeds