Status/Clock Select Register B; Status/Clock Select Register A Format - Digital Equipment VAXstation I Service Manual

Table of Contents

Advertisement

PROGRAMMING INFORHATIPN
READ:
15
08
07
06
OS
04
03
02
01
00
+· - .......... - ....... - - ........ -+·. ·+· - -+- -
·+·. ·+·. ·+· - ·+·.
·+·.
·+
not used
iRXBIFERIPERIOERITXEITXRjFFL!RXRI
+· - - .... - ...... - .. - ....... - - - - . ·+·. ·+·.
·+·. ·+·. ·+·. ·+· - ·+·. ·+· -
·+
WRITE:
15
08
07
04
03
00
+· ..... - ...... - ... - . - ......... - ·+· - ...... - .....
·+· .............
·+
not used
iRX CLOCK SELECTITX CLOCK SELECT!
+································+···············+···············+
ADDRESS
=
CSR BASE
+
34
Figure 2·9:
Status/Clock Select Register A Format
Table 2·13:
Status/Clock Select Reqister A Bits
+· •.••.• ·+· - ..... ·+· ....... - - ..... - . - - ............... - ...... - .. ·+
I BITS
!
ACCESS i DESCRIPTION
!
+· ...... ·+· ...... ·+· ... - .. - ...... - ... - - .. - ....... - . - . - . - ... - ... ·+
<15:08>
(not used)
<07>
READ
Received break (1 •yes).
<06>
READ
Framing error (1 •yes).
<05>
READ
Parity error (1 •yes).
<04>
READ
Overrun error (1 •yes).
<03>
READ
Transmitter empty (1 =yes).
<02>
READ
Transmitter ready (1 =yes).
<01>
READ
FIFO full (1 =yes).
<00>
READ
Receiver ready (1 =yes).
<07:04>
WRITE
Receiver clock select (1001
=
4800 baud).
<03:00>
WRITE
Transmitter clock select (1001
=
4800 baud).
+········+········+·············································+
2.1.6.4
Status/Clock Select Reqister B . (ADDRESS
=
CSR
BASE
+
50) See Status/Clock Select Register A
2-14