MAINTENANCE
Table 3·11:
Troubleshooting Flow (continued)
.... ·+· ..... - - . - - - . - - - - - - - - - - - - - - - - - - - - . - - - - - - - - - - - - - - - - -+- - - - - - -
STEP !PROCEDURE/DECISION
!BRANCH
- - • - -+- - - . - - - - - - - - • - - - - - - . - . - • - - - - • - - - - - - - - - - - - - - - - - - - - - -+- - - - - ••
25
26
Is following error message true?
INVALID FILENAME
Re-enter correct filename.
Return to START
Is following error message true?
PROGRAM IMAGE DOES NOT FIT IN AVAILABLE MEMORY
More physical memory is required
~or
this boot.
Return to START
N
•>
26
N •> 27
27
FATAL SYSTEM ERROR.
Possible multiple failures. The following sequence is
recommended:
a)
Reduce system to minimum configuration:
o
CPU
o
MSVll·QA
(1)
o
RQDXl
o
RXSO
o
VCBOl
b)
Follow troubleshooting flow from START.
c)
Replace failed unit.
d)
Re-install other FRUs, one-at-a-time.
e)
Verify each re-installed unit, by
repeating
steps
b)
through d) .
. . . . . ·+· - - .. - ............. - ...... - - .... - .... - - . - .. - ..
·+·. - ...... .