Monitor; Emi Screen - Digital Equipment VAXstation I Service Manual

Table of Contents

Advertisement

RB PLACEMENT
5.
Turn-on system and monitor
power.
run.
Microverify
should
6.
Run Macroverify.
4.8
MONITOR
4.8.l
~onitor
Cover Removal
l.
Place the monitor on
its
CRT
face
on
a
level
work
surfacl!.
WARRING - CRT Face
The integral CRT bezel is designed to
keep
the
CRT
face
above
the work surface; however, the
work surface under the CRT face should be
clear
of
any
debris.
In addition, it is recommended
that rough work surfaces be covered
to
prevent
any unnecessary scratches on the bezel.
2.
To remove the tilt-swivel base from the
monitor
cover,
remove
the
four
mounting
feet from the monitor.
The
mounting feet are finger tight.
3.
Remove the four philips-head screws from the rear of the
cover.
4.
Lift the cover off the monitor compartment.
4.8.2
EMI Screen
WARNING - CRT Neck
With the EMI screen removed, the neck of the
CRT
is
exposed
and
can be broken.
Be very careful
when removing modules or passing tools
over
the
monitor compartment.
1.
With the cover removed, place the monitor in its
normal
viewing position.
2.
Loosen the· six screen hold-down screws.
3.
Remove the EMI screen.
4-36

Advertisement