Table 3·11:
Troubleshooting Flow
- • - . -+- - - - - - - - - - - - - - - .. - - .. - - •• - - • - - . - - - - - - - - - - - - - - - - . - - ·+· - - - - - •
STEP
I
PROCEDURE/DECISION
I
BRANCH
- - - - -+- - - - - - - - - - • - - - • - • - - - • - - • - - - - - • - - - - - - - - - - - • - • - - - - - • -+- - - - - - -
START Turn system power ON.
Does system bootstrap?
N •>
l
Is the system operating reliably?
N •> 20
DONE
l
Is DC OK LED ON?
"MICROVERIFY STARTED" displayed on monitor?
Garbled or no monitor display?
Error number in Microverify LED display?
Error message dispalyed on monitor?
2
Is AC power switch lighted?
Both fans turning?
Turn power OFF.
Remove all modules except CPU.
Turn power ON.
Is DC OK LED ON?
a)
Turn power OFF.
b)
Re-install one module in backplane.
c)
Turn power ON.
d)
Is DC OK LED ON?
Repeat a), b), c) until d) =NO
3
Check: AC wall receptacle
AC power cord
AC circuit breaker
Power-on switch
AC power switch
4
Possibly power supply and/or fan.
5
6
Replace fan; or
Replace H7864 power supply.
Return to START
Replace H7864 power supply.
Return to START
Replace failed module.
Is DC OK LED ON'?
Return to START
3-29
N •>
2
N •>
8
y
=> 10
y
•> 14
y
=> 19
N
->
20
N ->
3
N
•>
4
N
•>
5
N
•>
6
N =,
7