Installing The System Into A Rack; Identifying The Sections Of The Rack Rails - Supermicro SUPERSERVER 1028U-E1CR4+ User Manual

Table of Contents

Advertisement

SUPERSERVER 1028U-E1CR(4/TP)+ User's Manual
2-5

Installing the System into a Rack

This section provides information on installing the chassis into a rack unit with the
rails provided. There are a variety of rack units on the market, which may mean
that the assembly procedure differs slightly. You should also refer to the installation
instructions that came with the rack unit you are using.
Note: This rail will fit a rack between 26" and 33.5" deep.
Stability hazard. The rack stabilizing mechanism must be in place, or the
rack must be bolted to the floor before you slide the unit out for servicing.
Failure to stabilize the rack can cause the rack to tip over.

Identifying the Sections of the Rack Rails

The chassis package includes two sets of rack rails, one set for the right side of the
chassis and one for the left. Each set consists of an inner rail that is fixed directly
to the chassis and an outer rail that attaches to the rack.
The inner rails are pre-attached and do not interfere with normal use of the chassis
if you decide not to install it into a
pre-attached to the
Figure 2-1. Identifying the Sections of the Rack Rails
rack.
Inner Rail--
chassis
Inner Rail
Extension--
attach to the
chassis
2-4
Outer Rails--
slide together
Front and Rear
Brackets--
attach to the rack