  • Page 1 SUPERSERVER ® 1028UX-LL1-B8 1028UX-LL2-B8 1028UX-LL3-B8 USER’S MANUAL...
  • Page 2 This product, including software and This manual is written for professional system integrators and PC technicians. documentation, is the property of Supermicro and/or its licensors, and is supplied only under a It provides information for the installation and use of the SuperServer license.
  • Page 3 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Table of Contents Notes Chapter 6: Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC119UTS-R751P-T server chassis. You should follow the procedures given in this chapter when installing, removing or reconfiguring hardl drives and when replacing system power supply units and cooling fans.
  • Page 4: Table Of Contents

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Table of Contents Table of Contents Chapter 3 System Interface Overview ......................3-1 Chapter 1 Introduction Control Panel Buttons ..................3-2 Control Panel LEDs ..................3-2 Overview ......................1-1 Overheating ..................... 3-3 Serverboard Features ..................1-2 Drive Carrier LEDs ..................
  • Page 5 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual 5-11 Installing Software ..................5-19 SuperDoctor® 5 .................... 5-20 5-12 Onboard Battery .................... 5-21 Chapter 6 Advanced Chassis Setup Static-Sensitive Devices .................. 6-1 Precautions ..................... 6-1 Removing Power from the System ..............6-2 Control Panel ....................6-2 Chassis Cover ....................
  • Page 6: Overview

    Chapter 1 Introduction Overview The SuperServer 1028UX-LL1-B8/1028UX-LL2-B8/1028UX-LL3-B8 is a high-end server comprised of two main subsystems: the SC119UTS-R751P-T 1U server chassis and the X10DRU-XLL dual processor serverboard. Please refer to our website for information on operating systems that have been certified for use with the system (www.supermicro.com).
  • Page 7: Serverboard Features

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 1: Introduction Serverboard Features Server Chassis Features At the heart of the 1028UX-LL1-B8/1028UX-LL2-B8/1028UX-LL3-B8 lies the The 1028UX-LL1-B8/1028UX-LL2-B8/1028UX-LL3-B8 is built upon the X10DRU-XLL, a dual processor serverboard based on the Intel® PCH C612 Express SC119UTS-R751P-T chassis. The following is a general outline of the main features chipset.
  • Page 8: Contacting Supermicro

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 1: Introduction Contacting Supermicro DDR3 NCSI Headquarters UART Address: Super Micro Computer, Inc. 980 Rock Ave. Port A San Jose, CA 95131 U.S.A. Port B Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Port B...
  • Page 9 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Notes...
  • Page 10: Chapter 2 Server Installation

    Chapter 2: Server Installation Chapter 2 Server Installation Overview This chapter provides a quick setup checklist to get your system installed into a rack. Be aware of the warnings and precautions mentioned in this chapter when installing the server into a rack. Unpacking the System You should inspect the box the chassis was shipped in and note if it was damaged in any way.
  • Page 11: Warnings And Precautions

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 2: Server Installation Warnings and Precautions Rack Mounting Considerations Ambient Operating Temperature Rack Precautions If installed in a closed or multi-unit rack assembly, the ambient operating • Ensure that the leveling jacks on the bottom of the rack are fully extended to temperature of the rack environment may be greater than the ambient temperature the floor with the full weight of the rack resting on them.
  • Page 12: Installing The System Into A Rack

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 2: Server Installation Installing the System into a Rack Installing the Optional Inner Rail Extensions Attaching the optional inner rail extensions allows you to pull the server farther out This section provides information on installing the chassis into a rack unit with the of the rack.
  • Page 13: Assembling The Outer Rails

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 2: Server Installation Assembling the Outer Rails Installing the Outer Rails onto the Rack Each outer rail comes in two sections that must be assembled before mounting Each end of the assembled outer rail includes a bracket with square pegs to fit into onto the rack.
  • Page 14: Installing And Removing The Chassis From A Rack

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 2: Server Installation Installing and Removing the Chassis From a Rack Installing the Server into a Telco Rack Installation into a Rack Optional brackets are needed to install the server to a telco (open type) rack.
  • Page 15 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Notes 2-10...
  • Page 16: Chapter 3 System Interface

    Chapter 3: System Interface Chapter 3 System Interface Overview The chassis includes: • A control panel on the front that houses power buttons and status monitoring lights • Status lights on externally accessable hard drives • Status lights for the power supply visible from the back of the chassis These elements are described in this chapter with possible responses.
  • Page 17: Control Panel Buttons

    For more information, consult the backplane user manual An overheat condition has occured. Continuously on and red at www.supermicro.com. (Click Support, then the Manuals link.) (This may be caused by cable congestion.) Blinking red (1Hz) Fan failure, check for an inoperative fan.
  • Page 18: Drive Carrier Leds

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Drive Carrier LEDs The chassis includes externally accessable SATA drives. Each drive carrier displays two status LEDs on the front of the carrier. • Green: When illuminated, this LED indicates drive activity. It blinks on and off when that particular drive is being accessed This function is controlled by the backplane.
  • Page 19: Chapter 4 Standardized Warning Statements For Ac Systems

    Only certified technicians should attempt to install or configure components. Read this chapter in its entirety before installing or configuring components in the Supermicro chassis. Some warnings may not apply for your system. These warnings may also be found on our website at http://www.supermicro.com/ about/policies/safety_information.cfm. Warning Definition Warning! This warning symbol means danger.
  • Page 20 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 4: Warning Statements for AC Systems Warnung ‫جسذٌة‬ ‫اصابة‬ ً‫تتسبب ف‬ ‫حالة ٌوكي أى‬ ً‫اًك ف‬ ‫خطز‬ ًٌ‫ٌع‬ ‫هذا الزهز‬ !‫تحذٌز‬ WICHTIGE SICHERHEITSHINWEISE ‫الذوائز‬ ‫بالوخاطز الٌاجوة عي‬ ‫ي على علن‬ ، ‫ك‬ ‫هعذات‬ ‫تعول على أي‬...
  • Page 21: Installation Instructions

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 4: Warning Statements for AC Systems Installation Instructions Circuit Breaker Warning! Warning! This product relies on the building's installation for short-circuit (overcurrent) Read the installation instructions before connecting the system to the power source. protection. Ensure that the protective device is rated not greater than: 250 V, 20 A.
  • Page 22: Power Disconnection Warning

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 4: Warning Statements for AC Systems ¡Advertencia! 경고! El sistema debe ser disconnected de todas las fuentes de energía y del cable 이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에 eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso 의존합니다.
  • Page 23: Equipment Installation

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 4: Warning Statements for AC Systems Equipment Installation Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door Warning! geschoold en gekwalificeerd personeel. Only trained and qualified personnel should be allowed to install, replace, or service Restricted Area this equipment.
  • Page 24: Battery Handling

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 4: Warning Statements for AC Systems Warnung ‫אזור עם גישה מוגבלת‬ Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. !‫אזהרה‬ Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers.
  • Page 25: Redundant Power Supplies (If Applicable To Your System)

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 4: Warning Statements for AC Systems Redundant Power Supplies (if applicable to your system) ‫امداد الطاقة‬ ‫بوحدات‬ ‫عدة اتصاالت‬ ‫جهاز‬ ‫ال‬ ‫يكون لهذا‬ ‫قد‬ ‫الكهرباء‬ ‫عن‬ ‫وحدة‬ ‫ال‬ ‫لعسل‬ ‫كافة االتصاالت‬ ‫يجب إزالة‬ 경고! Warning! This unit might have more than one power supply connection.
  • Page 26: Comply With Local And National Electrical Codes

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 4: Warning Statements for AC Systems Attention ‫מתח בפנל האחורי‬ L'équipement doit être installé conformément aux normes électriques nationales et locales. !‫הרה‬ ‫אז‬ ‫קיימת סכנת מתח בפנל האחורי בזמן תפעול המערכת. יש להיזהר במהלך‬ ‫תיאום חוקי החשמל הארצי‬...
  • Page 27: Hot Swap Fan Warning (If Applicable To Your System)

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 4: Warning Statements for AC Systems ¡Advertencia! 警告 當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他 Al deshacerse por completo de este producto debe seguir todas las leyes y 物品太靠近風扇。 reglamentos nacionales. Warnung Attention Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis La mise au rebut ou le recyclage de ce produit sont généralement soumis à...
  • Page 28: Power Cable And Ac Adapter

    UL ou CSA câbles certifiés qui ont UL ou CSA indiqué sur le code power cables and AC adaptors. Using any other cables and adaptors could cause pour tous les autres appareils électriques que les produits désignés par Supermicro a malfunction or a fire. Electrical Appliance and Material Safety Law prohibits the seulement.
  • Page 29 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Notes 4-20...
  • Page 30: Handling The Serverboard

    Chapter 5: Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to install processors and heatsinks to the X10DRU-XLL serverboard, connect the data and power cables and install add-on cards. All serverboard jumpers and connections are described and a layout and quick reference chart are included in this chapter.
  • Page 31: Processor And Heatsink Installation

    Install the processor into the CPU socket before installing the heatsink. 4. Pop the plastic cap marked IMPORTANT! • Refer to the Supermicro website for updates on CPU support. "Warning" out of the load plate. 5. Holding the CPU carefully above the socket, orient the CPU so...
  • Page 32: Installing A Passive Cpu Heatsink

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 5: Advanced Serverboard Setup Installing a Passive CPU Heatsink 1. Do not apply any thermal grease to the heatsink or the CPU die; the required amount has already been applied. Gently close the load plate.
  • Page 33: Connecting Cables

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 5: Advanced Serverboard Setup Connecting Cables Installing Memory Now that the processors are installed, the next step is to connect the cables to the Note: The system comes with memory already preinstalled. Follow the instructions serverboard.
  • Page 34: Serverboard Details

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 5: Advanced Serverboard Setup Serverboard Details Connector Description COM1 COM (Serial) Port 1 Figure 5-4. SUPER X10DRU-XLL Layout FAN1 - FAN8 System Cooling Fan Header IPMI LAN Dedicated IPMI LAN Port COM1 SXB1_1 SXB1A JIPMB1 I-SATA0~5 SATA 3.0 Ports (supported by Intel PCH)
  • Page 35: Connector Definitions

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 5: Advanced Serverboard Setup Connector Definitions HDD LED The HDD LED connection is located HDD/UID Switch Pin Definitions (JF1) on pins 13/14 of JF1. Attach a hard Power Connectors Pin# Definition drive LED cable to display HDD activ- The X10DRU-XLL serverboard supports the following power configurations: ity.
  • Page 36 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 5: Advanced Serverboard Setup Reset Button Internal Speaker Internal Speaker Pin Definition Reset Button The Reset Button connection is lo- The Internal Speaker, located at SP1, Pin Definitions (JF1) Pin# Definitions cated on pins 3 and 4 of JF1. Attach...
  • Page 37: Jumper Settings

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 5: Advanced Serverboard Setup Jumper Settings Unit Identifier Buttons/UID LED Indicators A rear unit identifier button (JUIDB2) is located next to the COM port. The rear Explanation of Jumpers UID LED (LED1) is located next to the rear UID button. Pressing the UID button causes the UID LED indicator turn on.
  • Page 38: Onboard Indicators

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 5: Advanced Serverboard Setup Onboard Indicators C Bus for VRM Jumpers JVRM1 and JVRM2 allow IPMI Dedicated LAN LEDs IPMI LAN Activity Indicator the BMC or the PCH to access CPU LED Settings and memory VRM controllers. See...
  • Page 39: 5-10 Sata Ports

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 5: Advanced Serverboard Setup 5-10 SATA Ports 5-11 Installing Software The Supermicro FTP site contains drivers and utilities for your system at ftp://ftp. supermicro.com. Some of these must be installed, such as the chipset driver. SATA 3.0 Ports After accessing the FTP site, go into the CDR_Images directory and locate the ISO Ten SATA 3.0 ports are located on the serverboard.
  • Page 40: Superdoctor® 5

    5-12 Onboard Battery SuperDoctor® 5 The Supermicro SuperDoctor 5 is a program that functions in a command-line Please handle used batteries carefully. Do not damage the battery in any way; a or web-based interface in Windows and Linux operating systems. The program damaged battery may release hazardous materials into the environment.
  • Page 41 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Notes 5-22...
  • Page 42: Chapter 6 Advanced Chassis Setup

    Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform maintenance on the SC119UTS-R751P-T chassis. The only tool required is a Phillips screwdriver. Your system may require the installation of processors, memory, drives or expansion cards.
  • Page 43: Removing Power From The System

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 6: Advanced Chassis Setup Chassis Cover Control Panel Release Buttons Hot-Swap Drive Bays (10) Ports PCI Slots Power Supplies Rear I/O Ports (see Figure 5-2) Figure 6-1. Chassis Front and Rear Views Removing Power from the System Before performing most setup or maintenance tasks, use the following procedure to ensure that power has been removed from the system.
  • Page 44: Installing Drives

    2. Use the handle to pull the drive carrier out of the chassis. Figure 6-4. Removing the Dummy Drive from a Carrier Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro website http://www.supermicro.com/products/nfo/storage.cfm...
  • Page 45: Internal Expansion Card

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 6: Advanced Chassis Setup 4. Insert the riser card into the serverboard expansion slot while aligning the riser card bracket with the rear of the chassis. The riser card bracket is toolless and has pins that snap into holes on the rear of the chassis.
  • Page 46: System Cooling

    Make sure the chassis top cover makes a good seal so the cooling air circulates properly through the chassis. 3. Replace the failed fan with an identical 4cm fan, available from Supermicro. 4. Push the new fan into the vacant space in the housing while making sure the...
  • Page 47: Installing The Air Shroud

    The PWR Fail LED will illuminate and remain on until the failed unit has been replaced. Replace with the same model. Replacement units can be ordered directly from Supermicro. Figure 6-10. Removing the Power Supply Replacing the Power Supply 1.
  • Page 48 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Notes 6-12...
  • Page 49: Chapter 7 Bios

    Chapter 7: BIOS Chapter 7 BIOS Introduction This chapter describes the AMI BIOS Setup utility for the X10DRU-X(LL). It also provides the instructions on how to navigate the AMI BIOS Setup utility screens. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated. Starting BIOS Setup Utility To enter the AMI BIOS Setup utility screens, press the <Del>...
  • Page 50: How To Change The Configuration Data

    <F2> at the appropriate time during system boot. This item displays the system time in HH:MM:SS format (e.g. 15:32:52). Note: For AMI UEFI BIOS Recovery, please refer to the UEFI BIOS Recov- ery User Guide posted @ http://www.supermicro.com/support/manuals/. Supermicro X10DRU-X BIOS Version Starting the Setup Utility This item displays the version of the BIOS ROM used in this system.
  • Page 51: Advanced Setup Configurations

    19 at bootup and allow the drives that are attached to these host adaptors to func- tion as bootable disks. If this item is set to Disabled, the ROM BIOS of the host Hyper-Speed is Supermicro's proprietary enterprise-class hardware acceleration adaptors will not capture Interrupt 19, and the drives attached to these adaptors technology.
  • Page 52 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 7: BIOS Clock Spread Spectrum Power Button Function Select Enable to enable Clock Spectrum support, which will allow the BIOS to moni- If this feature is set to Instant_Off, the system will power off immediately as soon tor and attempt to reduce the level of Electromagnetic Interference caused by the as the user presses the power button.
  • Page 53 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 7: BIOS  Advanced Power Management Configuration Direct Cache Access (DCA Support) Select Enabled to use Intel's DCA (Direct Cache Access) Technology to improve This section is used to configure the following CPU Power Management settings.
  • Page 54: Chipset Configuration

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 7: BIOS CPU C6 Report Package Clamping Limit1 Select Enabled to allow the BIOS to report the CPU C6 State (ACPI C3) to the Use this item to set the limit on power performance states for the run-time proces- operating system.
  • Page 55 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 7: BIOS II01 PORT 1A Link Speed No Snoop This item configures the link speed of a PCI-E port specified by the user. The Select Enable to support no-snoop mode for each CB device. The options are options are Gen 1 (Generation 1) (2.5 GT/s), Gen 2 (Generation 2) (5 GT/s) and...
  • Page 56: Dimm Information

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 7: BIOS Link Frequency Select Set Throttling Mode Use this item to select the CPU Frequency. The options are 6.4 GB/s, 8.0 GB/s, Throttling improves reliability and reduces power consumption in the proces- 9.6 GB/s, Auto, Auto Limited.
  • Page 57: South Bridge Configuration

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 7: BIOS Patrol Scrub XHCI Hand-Off Patrol Scrubbing is a process that allows the CPU to correct correctable memory This is a work-around solution for operating systems that do not support XHCI (Ex- errors detected on a memory module and send the correction to the requestor tensible Host Controller Interface) hand-off.
  • Page 58 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 7: BIOS Serial ATA Port 0~ Port 5 Configure SATA as This item indicates that a SATA port specified by the user is installed (present) Select IDE to configure a SATA drive specified by the user as an IDE drive. Select or not.
  • Page 59 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 7: BIOS Port 0 ~ Port 5 SATA Device Type sSATA Port 0 ~ Port 1 Hot Plug Use this item to specify if the SATA port specified by the user should be con- Select Enabled to enable hot-plugging support for a port specified by the user, nected to a Solid State drive or a Hard Disk Drive.
  • Page 60 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 7: BIOS • PCIe/PCI/PnP Configuration Model number of drive and capacity • Software Preserve Support The following PCI information will be displayed: • PCI Bus Driver Version sSATA Port 0~ Port 1 Select Enabled to enable an sSATA port specified by the user. The options are Above 4G Decoding (Available if the system supports 64-bit PCI decoding) Disabled and Enabled.
  • Page 61 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 7: BIOS PCI / PCIX / PCIe Slot 1 OPRPM Change Port 1 Settings/Change Port 2 Settings PCI / PCIX / PCIe Slot 2 OPRPM This feature specifies the base I/O port address and the Interrupt Request address PCI / PCIX / PCIe Slot 3 OPRPM of Serial Port 1 or Serial Port 2.
  • Page 62 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 7: BIOS Putty KeyPad client computer. A lower transmission speed may be required for long and busy lines. The options are 9600, 19200, 38400, 57600 and 115200 (bits per second). This feature selects Function Keys and KeyPad settings for Putty, which is a terminal emulator designed for the Windows OS.
  • Page 63 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 7: BIOS Parity Redirection After BIOS Post A parity bit can be sent along with regular data bits to detect data transmission Use this feature to enable or disable legacy Console Redirection after BIOS errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits POST (Power-On Self-Test).
  • Page 64 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 7: BIOS Trusted Computing (Available when a TPM device is detected) Select VT-UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes. The options are ANSI, VT100, VT100+, and VT-UTF8. TPM Support...
  • Page 65: Event Logs

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 7: BIOS Event Logs Erasing Settings Erase Event Log Use this feature to configure Event Log settings. Select Enabled to erase all error events in the SMBIOS (System Management BIOS) log before an event logging is initialized at bootup. The options are No and Yes.
  • Page 66: Ipmi

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 7: BIOS Date/Time/Error Code/Severity Select No to keep all system event logs after each system reboot. The options are No, Yes, On next reset, and Yes, On every reset. IPMI When SEL is Full This feature allows the user to determine what the BIOS should do when the sys- tem event log is full.
  • Page 67: Security Settings

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 7: BIOS This item displays the Station MAC address for this computer. Mac addresses are Use this feature to set the administrator password which is required before entering 6 two-digit hexadecimal numbers. the BIOS setup utility. The length of the password should be from 3 characters to 20 characters long.
  • Page 68 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Chapter 7: BIOS • Boot Option File Path Dual Boot Order #1 • Create Dual Boot Order #2 After the driver option name and the file path are set, press <Enter> to enter to • Dual Boot Order #3 submenu and click OK to create the new boot option drive.
  • Page 69: Save & Exit

    SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Save & Exit Select the Save & Exit tab from the BIOS setup screen to configure the settings below. Discard Changes and Exit Select this option to quit the BIOS setup without making any permanent changes to the system configuration, and reboot the computer.
  • Page 70: Appendix A Bios Error Beep Codes

    Appendix A: BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the Power-On Self-Test (POST) routines, which are performed at each system boot, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue to boot.
  • Page 71 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Notes...
  • Page 72: Appendix B System Specifications

    Appendix B: System Specifications Appendix B System Specifications Processors Two Intel E5-2600 v4 series processors in R3-LGA 2011 type sockets Note: Please refer to Chapter 1 for the specific processors pre-installed in each system.. Chipset Intel PCH C612 Express BIOS 16 MB SPI AMI BIOS SM Flash UEFI BIOS ®...
  • Page 73 See www.dtsc.ca.gov/hazardouswaste/perchlorate” (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency com- munication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage.
  • Page 74 SUPERSERVER 1028UX-LL1-B8/LL2-B8/LL3-B8 User's Manual Notes...