5. Cabling: Test Access SIM
Connecting Alarm Out to the CO Alarm System
The following procedure is optional. Follow this procedure only if you want to
connect to a CO alarm system. See
Procedure
To connect the 8820 BAC to a CO alarm system:
Connecting an MCP to an SNMP Management System
Procedure
To connect an MCP card to an SNMP management system, or for Telnet access to
the MCP card:
5-6
1. Plug an 8-pin modular cable into the Alarm Out port of the chassis.
2. Dress the cable to the right in the cable tray.
3. Connect the other end of the cable to the desired CO alarm system inputs.
1. Plug an 8-pin modular cable into LAN Slot 9 of the SIM, which corresponds to
the MCP card in Slot 9 of the chassis.
2. Dress the cable to the right and through the cable retainer.
3. Plug the other end of the cable into the 10/100BaseT hub connected to the
SNMP management system network.
November 2004
Alarm Out Connector
in Appendix A, Pinouts.
8820-A2-GN20-80