Alarm In Connector

The ALARM IN connector (8820-S1-905) supports two alarm-in circuits.

Alarm Out Connector

The ALARM connector (8820-S1-902) or ALARM OUT connector (8820-S1-905)
consists of two sets of dry contact closures on an 8-pin jack. The Alarm leads
report major and minor alarms to a CO alarm system. The following table lists the
pin assignments for the 8-pin jack.
8820-A2-GN20-80
Pin Number
Use
1
Alarm Sense 1 +
2
Alarm Sense 1 –
3
Reserved
4
Reserved
5
Reserved
6
Reserved
7
Alarm Sense 2 +
8
Alarm Sense 2 –
Pin Number
Use
1
Not Connected
2
Closed on Major Alarm
(Normally Open)
3
Common on Major Alarm
4
Open on Major Alarm
(Normally Closed)
5
Closed on Minor Alarm
(Normally Open)
6
Common on Minor Alarm
7
Open on Minor Alarm
(Normally Closed)
8
Not Connected