ACCULINK 3350 E1 NTU

Performance Reports

Network performance is continuously monitored and
maintained in network registers (NET) and G.703 DTE
registers (DTE). Registers shown on the front panel LCD
are listed in Table 4-4.
NET and DTE registers are status registers that collect
performance data for the previous 24-hour period.
Performance data is updated in 15-minute intervals. After
15 minutes, the current interval is rolled over into a set of
accumulator registers that represent the previous 96
15-minute intervals for the register. An interval total of
how many of the 96 registers contain valid data is also
kept, as well as a 24-hour total for each accumulator
register.
NOTE
The following procedure is an
example only. Screen displays
may vary depending on the
configuration of the E1 NTU.
The procedure for displaying DTE
registers is similar to this
example.
To display network (NET) performance,
1. From the top-level menu screen, select Stat.
E1 HDSL NTU
Stat
F1
2. From the Status screen, press the
Perf selection appears on the screen.
4-6
Test
Cnfig
F3
F2
key until the
June 1996
3. From the Status screen, select Perf.
Status:
DevHS STest Perf
F1
F2
4. Select NET registers.
Performance:
NET
DTE
F1
F2
5. From the NET Registers screen, select E1 to view
the registers that apply to the E1 (G.704) network
interface. Select Lp1 or Lp2 to view the HDSL
loop 1 or loop 2 network interface registers. (In
the following example, E1 is selected.)
NET Registers:
E1
Lp1
F1
F2
6. From the E1 Registers screen, press F1 to view
current registers (go to Step 7), press F2 to view
24-Hour Totals (go to Step 8), or press F3 to view
15-Minute Interval Registers (go to Step 9).
E1 Registers:
Cur
24Tot
F1
F2
F3
F3
Lp2
F3
Intvl
F3
3350-A2-GB20-10