Hdsl Loop Performance - Paradyne 3350 User Manual

Zhone acculink 3350 ntu: user guide
Hide thumbs Also See for 3350:
Table of Contents

Advertisement

HDSL Loop Performance

Use the HDSL Loop Performance branch to view the
signal quality and loop loss messages for each loop on the
local E1 NTU. Table 4-3 lists these messages.
To display HDSL loop performance,
1. From the top-level menu screen, select Stat.
E1 HDSL NTU
Stat
F1
2. From the Status screen, select HDSL.
Status:
HDSL DevHS STest
F1
Message
Lp1 SigQ= xx
The loop 1 signal quality value ( xx ) is 0 to 10. A value of 10 indicates the noise margin is 9 dB or
more above the margin needed to produce a bit error rate of approximately 10
9 indicate noise margins of 1 to 8 dB above this margin. A value of 1 indicates the noise margin is
less than or equal to the margin needed to produce a bit error rate of approximately 10
0 indicates the loop is out of synchronization or the noise margin is unavailable.
Lp2 SigQ= xx
The loop 2 signal quality value ( xx ) is 0 to 10. (See the Lp1 SigQ description above.)
Lp1 Loss= xx
The loop 1 loss value ( xx ) is 0 to 40. The value indicates an approximation (+/– 2 dB) of the loss
that the E1 NTU detects at the interface to loop 1. Due to bridge taps on the loop, this value could
be different at each end of the loop. (Values above 40 are invalid.)
Lp2 Loss= xx
The loop 2 loss value ( xx ) is 0 to 40. (See the Lp1 Loss description above.)
3350-A2-GB20-10
Test
Cnfig
F3
F2
F2
F3
Table 4-3
HDSL Loop Performance Messages
June 1996
HDSL messages appear on Line 2 of the LCD.
The E1 NTU is polled for current status every ten
seconds. If the status has changed from the last
poll, the HDSL screen is updated.
3. Use the scroll keys, to scroll additional HDSL
messages onto the LCD.
HDSL:
Lp1 SigQ= xx
F1
Description
Maintenance
F2
F3
-7
. The values of 2 to
-7
. A value of
4-5

Advertisement

Table of Contents
loading