ACCULINK 3350 E1 NTU
Near End Group – "dsx1TimeElapsed" Object
(dsx1ConfigEntry 3)
Applies to the network interface only. An error status is
returned if access is attempted for the G.703 DTE
interface.
Near End Group – "dsx1ValidIntervals" Object
(dsx1ConfigEntry 4)
Applies to the network interface only. An error status is
returned if access is attempted for the G.703 DTE
interface.
Near End Group – "dsx1LineType" Object
(dsx1ConfigEntry 5)
This object corresponds to the NET Framing/DTE
Framing configuration options for the E1 interfaces on the
E1 NTU. Only the following values are supported by the
E1 NTU.
dsx1E1(4) – Indicates non-CRC-4 framing.
dsx1E1-CRC(5) – Indicates CRC-4 framing.
Near End Group – "dsx1LineCoding" Object
(dsx1ConfigEntry 6)
This object corresponds to the DTE Coding
configuration option on the E1 NTU. Only the following
values are supported by the E1 NTU.
dsx1HDB3(3) – Indicates HDB3 line coding.
dsx1AMI(5) – Indicates AMI line coding (for DTE
only, not available for NET).
Near End Group – "dsx1SendCode" Object
(dsx1ConfigEntry 7)
This object specifies the test patterns/codes being sent
over the network interface. These tests are not supported
on the G.703 DTE interface. Only the following values
are supported by the E1 NTU.
dsx1SendNoCode(1) – Specifies that the interface
is sending normal or looped data. Setting the
interface to this value stops an active "send pattern"
test on the interface. This is the only value
supported by the G.703 DTE interface.
E-8
dsx1SendOtherTestPattern(8) – Specifies that the
network interface is sending a 1-in-8 or 32767 test
pattern. This value is read-only. An attempt to write
this value returns a badValue response.
Near End Group – "dsx1CircuitIdentifier" Object
(dsx1ConfigEntry 8)
This object is only supported on the network interface.
Near End Group – "dsx1LoopbackConfig"
Object (dsx1ConfigEntry 9)
This object specifies the loopback state of the E1
interfaces. Only the following values are supported by the
E1 NTU.
dsx1NoLoop(1) – The E1 interface is not in a
loopback state.
dsx1PayloadLoop(2) – Specifies that a Payload
Loopback (PLB) is active for the network interface
or a Repeater Loopback (RLB) is active for the
G.703 DTE interface.
dsx1LineLoop(3) – Specifies that a Line Loopback
(LLB) is active for the network interface or a DTE
Loopback (DLB) is active for the G.703 DTE
interface.
Near End Group – "dsx1LineStatus" Object
(dsx1ConfigEntry 10)
This object specifies the line (alarm) status of the E1
interfaces. Only the following values are supported by the
E1 NTU. More than one value may be active at a time.
dsx1NoAlarm(1) – No alarm present.
dsx1RcvFarEndLOF(2) – A Remote Alarm
Indication (RAI) signal is being received.
dsx1RcvAIS(8) – An Alarm Indication Signal
(AIS) is being received.
dsx1LossOfFrame(32) – An Out Of Frame (OOF)
condition has persisted for more that 2.5 seconds.
dsx1LossOfSignal(64) – A Loss of Signal (LOS)
condition has persisted for more that 2.5 seconds.
dsx1LoopbackState(128) – The near end of the E1
interface is in a loopback state.
June 1996