ACCULINK 3350 E1 NTU
Message
EER at DTE
An Excessive Error Rate condition has been detected on the G.703 DTE interface. The condition is
cleared when the error rate falls below the threshold value (10
RAI at Net
A Remote Alarm Indication is being received by the network interface.
RAI at DTE
A Remote Alarm Indication is being received by the G.703 DTE interface.
MFA at Net
A Multiframe Alarm condition (2 consecutive errored multiframe alignment signals, or two
consecutive multiframes with all zeros in time-slot 16) has been detected on the network interface.
The condition is cleared when realignment (or time-slot 16 correction) occurs.
MFA at DTE
A Multiframe Alarm condition has been detected on the G.703 DTE interface. The condition is
cleared when realignment (or time-slot 16 correction) occurs.
RMA at Net
A Remote Multiframe Alarm signal is being received by the network interface.
RMA at DTE
A Remote Multiframe Alarm signal is being received by the G.703 DTE interface.
PORT SNMP Down
The SNMP management link is in a down state for PORT (where PORT is COM or AUX). This
condition occurs if the PORT is configured for SNMP, and communication between the
management system and the E1 NTU is not currently possible for this port. For the AUX port, this
condition is detected only when a device reset or power-up occurs.
Selftest failed
A failure was detected during the power-on self-test. Select STest (in the Stat branch) to display
more information about the failure.
DevFail xxxxxxxx
An internal error has been detected by the operating software. An 8-digit code appears for use by
AT&T Paradyne service personnel. The condition is cleared by resetting the device.
Download failed
A download attempt was interrupted and failed to complete. The condition is cleared by resetting
the device.
Test in progress
A test is currently active. Select Tstat (in the Stat branch) to display more test information.
Lp1/Lp2 Reversed
The loop 1 and loop 2 connections on the HDSL network are reversed.
NTU Operational
This message only appears if the unit is configured as an NTU and there are no valid alarm or
status messages.
LTU Operational
This message only appears if the unit is configured as an LTU and there are no valid alarm or
status messages.
4-4
Table 4-2
(2 of 2)
Health and Status Messages
Description
June 1996
-4
) for 5 seconds.
3350-A2-GB20-10